Protection function
FA.02
selection 3
Energy consumption
FA.08
braking action voltage
Reserve
FA.09
Busbar undervoltage
FA.10
protection value
Instantaneous
power-down
FA.11
deceleration action
voltage threshold
Instantaneous
power-down main circuit
FA.12
target voltage
AC80T Tower Crane Purpose VFD Manual
0: Emergency stop and
alarm
1: Emergency stop and
alarm
2: Limiting current and run
LED"1000"digit: Motor
overload action selection
0: Emergency stop and
alarm
1: Emergency stop and
alarm
2: Limiting current and run
3: Motor overload protection
off
LED "0"digit: Inverter OH
action selection
0: Emergency stop and
alarm
1: Emergency stop and
alarm
2: Limiting current and run
LED "10"digit: Input lack
phase protection selection
0: Invalid
1: Valid
LED"100"digit: Output lack
phase protection selection
0: Invalid
1: Lack phase detection
valid, no open brake signal
2: Lack phase detection
valid, associated with open
brake
LED"0000"digi: Reserved
115.0~140.0%
50.0~100.0%
0~200%
0~200%
26
0210
120.0%
60.0%
20%
90%