F5.08
Motor stator resistance
F5.09
Motor Rotor resistance
Motor stator-rotor
F5.10
inductance
Motor stator-rotor
F5.11
mutual inductance
Motor parameter
self-adjustment
F5.12
selections
F5.13
Rated field component
F5.14
Torque component
F5.15
PG selection
F5.16
PG weekly pluse time
PG wire breakage
F5.17
detection time
Vector control parameter set
No.
Function description
ASR (velocity loop)
F6.00
proportional gain 1
ASR (velocity loop)
F6.01
integral time 1
ASR (velocity loop)
F6.02
derivative time 1
ASR filter time 1
F6.03
ASR switch frequency 1
F6.04
ASR (velocity loop)
F6.05
proportional gain 2
ASR (velocity loop)
F6.06
integral time 2
ASR (velocity loop)
F6.07
derivative time 2
AC80T Tower Crane Purpose VFD Manual
0.001~65.000
0.001~65.000
0.1~6500.0mH
0.1~6500.0mH
0: No operation
1: Rotary self learning
2: Static self learning
0~1000
0~2000
LED "0"digit: Sensor phase
0: Single phase input
1:Two phase input
LED "10"digit: Sensor phase
adjustment
0:Same direction
1:Opposite direction
LED "100"digit: Sensor wire
breakage detection
0: Wire breakage detection
off
1: Wire breakage detection
on
LED"1000"digit:PG feedback
channel
0:PG interface
1:PUL interface
0~60000
0.100~60.000s
Range of setting and
definition
0.00~1.00
0.01~10.00s
0.0~100.0
0.000~0.100s
0.00~50.00Hz
0.00~1.00
0.01~10.00s
0.0~100.0s
24
Model set
Model set
Model set
Model set
0
190
800
0001
1024
2.000s
Pr
Comm
Factory
op
unicat
default
ert
y
0.10
0.50
0.0
0.005s
5.00Hz
0.10
0.50
0.0s
ion
add.