Switch terminal parameter set
No.
Function description
Multifunction input
F2.00
terminal 1(X1)
Multifunction input
F2.01
terminal 2(X2)
Multifunction input
F2.02
terminal 3(X3)
Multifunction input
F2.03
terminal 4(X4)
Multifunction input
F2.04
terminal 5(X5)
Multifunction input
F2.05
terminal 6(X6)
Multifunction input
F2.06
terminal 7(X7)
Multifunction input
F2.07
terminal 8(X8)
X1~X4 input terminal
F2.09
filter time
X5~X8 input terminal
F2.11
filter time
F2.29
Output terminal 1(Y1)
F2.30
Output terminal 2(Y2)
Relay output terminal
F2.31
(TA-TB-TC)
Upward start frequency
F2.32
Upward start frequency
F2.33
delay time
Upward brake-releasing
F2.34
current value
Upward brake-releasing
F2.35
current value hold time
Downward start
F2.36
frequency
Downward start
F2.37
frequency delay time
Downward loose-brake
F2.38
current value
Downward loose-brake
F2.39
current value hold time
Upward stop-band
F2.40
brake frequency
AC80T Tower Crane Purpose VFD Manual
Range of setting and
definition
0: No function
1: FWD
2: REV
3:Three lines operation
control
4: FWD inching running
5: REV inching running
6:Free stop
7:Emergency stop
8:Fault reset
9: External fault input
15: Multistage speed
terminal 1
16: Multistage speed
terminal 2
17: Multistage speed
terminal 3
18: Multistage speed
terminal 4
46: Brake failure detection
0.000~60.000s
0.000~60.000s
0: No output
3:Fault trip alarm 1(alarm
while fault self-recover)
9: FDT function output
20:Hoist band-brake logic
control
29: Phase fault output
30: Brake failure
maintenance
0.00~50.00Hz
0.00~10.00s
0.00~500.0%
0.00~10.00s
0.00~50.00Hz
0.00~10.00s
0.00~500.0%
0.00~10.00s
0.00~50.00Hz
19
Pr
Com
Factory
op
munic
default
ert
ation
y
add.
1
2
15
16
17
18
8
46
0.030s
0.010s
3
30
20
4.00Hz
0.6
50.0%
0.10
3.50Hz
0.7
50.0%
0.10
3.50Hz