Keyboard numbers
F0.08
set the frequency
F0.09
Max. frequency
Upper limit frequency
F0.10
source selection
Upper limit frequency
F0.11
number setting
F0.12
Lower frequency
Lower frequency
F0.13
operation mode
F0.14
ACC time 1
F0.15
DEC time 1
F0.17
Carrier frequency
Carrier frequency
F0.18
PWM characteristic
selection
Parameter
F0.19
initialization
AVR function
F0.20
selection
AC80T Tower Crane Purpose VFD Manual
0.00~Upper limit
0.00~320.00Hz
0:Upper limit frequency number
given
Lower frequency~Max.
frequency output
0.00~Upper limit frequency
0: Stop
1: According to lower frequency
operation
0.01~650.00s
0.01~650.00s
0.6~15.0kHz
LED "0" digit:
0: Unrelated to temperature
1: Related to temperature
LED "10" digit:
0: Unrelated to output frequency
1: Related to output frequency
LED "100" digit:
0: Fixed carrier
1: Random carrier
LED "1000": PWM
0: PWM mode 1
1: PWM mode 2
2: PWM mode 3
0: No action
1: Recovery factory setting
2: Clear malfunction records
0: Invalid
1: All valid
2: Invalid in DEC only
16
10.00Hz
90.00Hz
0
90.00Hz
0.00Hz
1
6.0
3.0
1.0
0000
0
1