Technical Data

)
Pump Module with Auto-Fill Shutoff
Maximum hydraulic input pressure
Pump wetted parts
Vent valve wetted parts
Reservoir wetted parts
Maximum delivery @ 60 cpm
Regulated hydraulic pressure operating range
Hydraulic flow rate operating range
Maximum hydraulic fluid temperature
Lubricant outlet pressure range
Fill port size - Auto-fill Shutoff
Hydraulic inlet port size
Hydraulic tank line size
Lubricant outlet port size
Grease capacity
Model 24Y407, 25C949
Model 24Y408, 25C948
Mounting holes for pump module
Reservoir diameter
Pump module height
Model 24Y407, 25C949
Model 24Y408, 25C948
Electrical requirements
Electrical power requirements
Filtration (hydraulic fluid)
Sound Pressure*
*Sound pressure reading taken with pump operating at 66 cycles per minute. Sound pressure measured per
CAGI-PNEUROP, 1971.
US
3500 psi
see manual 312350
see manual 309099
steel, buna-n rubber
3
1.1 lb/min, 34.8 in
/min
250 to 350 psi
0.5 to 3.0 gpm
200°F
2500 to 3500 psi
3/8 inch npt (F
. 2, S, page 7)
IG
3/8 inch nps swivel (F
IG
3/4 inch nps swivel (F
IG
1/2 inch nps swivel (F
IG
90 lb.
60 lb.
six, 7/16 inch holes on 13 7/8 inch bolt circle
12 3/4 inch
42.75 inch
35.15 inch
Timed 24 VDC signal
14.7 Watts
10µ (microns) or better
77 dB(A)
Metric
24.0 MPa, 240 bar
3
570 cm
/min
1.7 to 2.4 MPa, 17.0 to 24.1 bar
1.9 to 11.4 liter/min
93.33°C
17.0 to 24.0 MPa, 170 to 240
bar
. 9, Y, page 11)
. 9, Z, page 11)
. 2 U, page 7)
41 kg
27 kg
324 mm
1086 mm
893 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dyna-star 24y407Dyna-star 25c948Dyna-star 25c949