Download Print this page

Technical Data; California Proposition 65 - Graco Dyna-Star 77X540 Instructions Manual

Hp vent valve kit

Advertisement

Parts
Ref Description
1
MANIFOLD, electric vent valve
2
VALVE, cartridge, 24VDC
3
VALVE, pressure relief, 3500 psi
4
SCREW, cap, socket, M8 x 1.25
8
O-RING
9
PLUG, pipe, 1/8 in. npt
10
PLUG, 1/4 in. npt
Accessories
Part No. Description
24N402
CABLE, 6 ft, vent valve, 2 pin for vent valve
control
77X546
CABLE, power extension, 15 ft (4.6m), Injec-
tor System

Technical Data

.
Vent Valve for Dyna-Star HP
Maximum working pressure*
Inlet/Outlet Sizes
Outlet (marked "0")
Inlet (refill - marked "1")
Pressure Relief Valve
Factory Set Pressure
Reset Pressure
Relief Rate**
Solenoid Valve
Flow**
Wetted materials
Weight
IP Rating
Solenoid Coil
24 VDC
*Dyna-Star HP Pump Models are rated for 5000 psi (34.47 MPa, 344 bar) maximum working pressure, however, when a vent valve is installed on
the HP Pump, the maximum working pressure must be reduced to 3500 psi (24.1 MPa, 241 bar).
**Flow capability depends on viscosity, type of fluid, temperature, etc.

California Proposition 65

CALIFORNIA RESIDENTS
WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.
332519J
Qty
1
1
1
3
2
1
1
US
3500 psi
4000 psi + 250 psi
80% of set pressure
0.1 gallons/minute @3500 psi
Up to gpm 0.2 gallons/minute,
3
40 in
/minute
Zinc plated steel, carbon steel, aluminum, fluoroelastomer, polyurethane
4.0 lbs
IP69K
Resistance (DC) (Ohms) @ 68°F (20°C)
28.8
1
10
4
24.1 MPa, 241 bar
3/8 in. npt(f)
3/8 in. npt(f)
27 MPa, 275 bar + 10%
0.4 liters/minute @24.1 MPa. 241 bar
0.65 liters/minute
1.8 kg
Initial Current Draw (Amps)
0.83
Parts
2
9
8
3
Metric
5

Advertisement