Auto-Fill Shut Off (S); Refilling The Reservoir - Graco Dyna-Star 24Y408 Instructions, Repair And Parts

10:1 pump module with auto-fill shutoff
Table of Contents

Advertisement

Auto-Fill Shut Off (S)

The Auto-Fill Shut Off (S) is used for refilling the grease
tank/reservoir in an automatic lubrication system.
NOTE: For systems without a fill valve, see Refilling
Systems without a Fill Valve instructions beginning on
page 13. For systems with a fill valve, see Refilling
Systems with a Fill Valve beginning on page 14.
As grease is added to the reservoir, it pushes the dia-
phragm up to the top of the reservoir. The diaphragm
then pushes the valve pin and closes the inlet fluid path.
When the fluid refilling path closes, the refilling line (D)
pressurizes and brings the refilling pump (P) to a pres-
surized stall condition.
NOTE: The operator must monitor system while filling
tank to reduce the risk of accidental fluid overflow.

Refilling the Reservoir

Refilling Systems without a Fill Valve
1. Connect refilling line (D) from remote filling station
pump (P) to the Auto-fill Shutoff inlet (F
7).
2. Turn on remote filling station pump (P) and fill reser-
voir (K) until the indicator pin on the Auto-Fill Valve
(S) pushes up as shown in F
refill pump (P) builds and the pump stalls.
pin
up
S
F
. 10
IG
3A3429C
. 2, page
IG
. 10. Pressure in the
IG
3. Turn off air supply to refill pump (P).
4. Relieve pressure between the remote filling station
pump (P) and the Auto-Fill Shut Off (S):
a. Open ball valve (bv) (F
released and excess fluid will drain out of the
drain tube (dt) and into the lubrication collection
container (N).
bv
H
F
. 11: In line installation shown
IG
Operation
. 11). Pressure will be
IG
G
dt
13