Web Tools - TagMaster XT-1 Installation Manual

Hide thumbs Also See for XT-1:
Table of Contents

Advertisement

XT-1 Installation Manual
EPC channel mask
EPC memory bank
EPC custom format
Table 15 RF/EPC Gen 2 settings
Tag Filter
4.2.3.5
The reader has a tag filter that controls how often tags are reported. The filter can be set to work in one of
the following modes:
Mode
Description
Off
Tags are reported every time they are read.
Periodic
Tags are reported periodically every "Filter timeout" milliseconds.
Once
Tags are reported once and have to be away for at least "Filter timeout" milliseconds
before they are reported again.
Report
Similar to once except that a TAGP GONE event is generated when the tag has been
away for "Filter timeout" milliseconds.
Table 16 Tag filter settings
It is possible to activate read beep and read blink to get an indication every time a tag is reported.
Data Selection
4.2.3.6
The data selection settings make it possible to specify which part of the data from the tag that shall be used
and how it shall be interpreted. All details are available on the Documentation page.

4.2.4 Web Tools

Read Tag
4.2.4.1
The "Read Tag" page makes it easy to read tags and display tag contents.
Figure 27 Read Tag
Sets which frequencies that shall be used in EU readers (not applicable in US
readers).
Specifies which parts of the EPC tag to read. The default setting
(EPC/SecureMarkID) makes it possible to read both EPC tags and
SecureMarkID tags.
Used to specify in detail which parts of the EPC tag to read. All details are
available on the Documentation page.