Configuration Easy Configuration - TagMaster XT-1 Installation Manual

Hide thumbs Also See for XT-1:
Table of Contents

Advertisement

XT-1 Installation Manual
4 Configuration
Easy Configuration
XT-1 can be configured to work with common access control systems using DIP switches S101:6-8. When
any of these switches are in the ON position, the reader is configured to report tags once, accept
SecureMarkID tags only, and use the specified Wiegand/Magstripe format.
XT-1
Assa ARX/RX WEB
(with 500RW22)
GND
0V
D0/CLK
D0
D1/DATA
D1
IN1+
12V
IN1-
LED_GREEN
IN2+
12V
IN2-
LED_RED
Settings
Configure the
ARX/RX WEB
system to use card
type Wiegand.
Tested
RX WEB PR300233
version
build-8418 version-
17.2.0.5
Built-in
2.2 kΩ to 5 V
pull-ups
S101
1
S301
1
Table 13 Easy Configuration
* To get all digits from the SecureMarkID tag, it is necessary to solder a strap at P14 on the DB-50W board.
Without this strap it is only possible to get the last four digits from the tag.
Bewator Entro
0V
D0/CLOCK
D1/DATA
N/C
N/C
N/C
N/C
Access System Configuration
Configure the
Bewator Entro
system to use
H10302 format.
Bewator Entro
6.55.011
3.3 kΩ to 5 V
New versions:
S101
ON
8
1
Older versions:
1
S301
ON
8
1
Cable Connections
Paxton Net2 plus
0V
Clock/D1
Data/D0
12V
Green LED
12V
Red LED
Configure the
Paxton system to
use reader type
"Clock & Data".
Net2 Lite version
4.28.8417
1 kΩ to 3.3 V
XT-1 DIP Settings
S101
ON
1
8
S101
ON
8
S301
ON
8
1
13-111 02, 2014-RO-012, 2014-04-30
RCO R-CARD M5
DC-
DATA0
DATA1
N/C
N/C
N/C
N/C
The RCO system
automatically
detects the Wiegand
format.
-
No pull-ups
With strap at P14*:
S101
ON
8
1
Without strap at
P14:
1
S301
ON
8
1
(with DB-50RW)
S101
ON
8
S101
ON
8
S301
ON
8
Page 22 of 32