Start; Information; Settings - TagMaster XT-1 Installation Manual

Hide thumbs Also See for XT-1:
Table of Contents

Advertisement

XT-1 Installation Manual

4.2.1 Start

The "Start" page provides TagMaster contact information.

4.2.2 Information

The "Information" page provides information about the system.

4.2.3 Settings

All configuration of the reader can be done on the "Settings..." pages. For all settings, it is possible to get
help by clicking on the question mark ( ). Click the "Save Settings" button to activate changed settings.
Click the "Factory Defaults" button to restore all settings on a page to factory defaults.
Security
4.2.3.1
The Security page makes it possible to change the TAGP password that is used to authenticate TAGP
clients. Make sure to set this password if the reader is connected on a public network!
Date & Time
4.2.3.2
The reader has a battery backed real time clock that can be set on the Date & Time page.
Interfaces...
4.2.3.3
4.2.3.3.1 Ethernet
The Ethernet page shows the current Ethernet settings and makes it possible to set IP address, netmask
and gateway.
4.2.3.3.2 Wieg/Mag
The Wiegand/Magstripe page contains all settings related to Wiegand/Magstripe. It is possible to select a
predefined format or to define a custom format. A description of all predefined formats and how to define a
custom format is available on the Documentation page.
The most common predefined formats can also be selected by setting DIP switches S101:6-8 as shown in
the table below. When any of these switches are in the ON position, the reader is also configured to report
tags once and only accept SecureMarkID tags (see §4.1 for more information).
D = Data from tag (bit for Wiegand/digit for Magstripe)
S = Value of Site code
E = Even parity bit, O = Odd parity bit, X = Bit included in parity calculation
B = Magstripe start character, F = Magstripe stop character, L = Magstripe LRC
Output Format
Disabled
W26S/H10301
S101
1
8
W26N/H10301
S101
1
8
Description
Wiegand/Magstripe output is disabled
26-bit Wiegand (8-bit site code, 16-bit data):
ESSSSSSSSDDDDDDDDDDDDDDDDO
ON
XXXXXXXXXXXXX-------------
-------------XXXXXXXXXXXXX
26-bit Wiegand (24-bit data, no site code):
EDDDDDDDDDDDDDDDDDDDDDDDDO
ON
XXXXXXXXXXXXX-------------
-------------XXXXXXXXXXXXX
13-111 02, 2014-RO-012, 2014-04-30
Page 24 of 32