TagMaster XT-1 Installation Manual page 16

Hide thumbs Also See for XT-1:
Table of Contents

Advertisement

XT-1 Installation Manual
Connections
Recommended / Max length
Wire size
Max Baud Rate
Table 8 RS485 connection overview
The default output of the RS485 interface is tag data in ASCII format. If SecureMarkID® tags from
TagMaster are being used (recommended) the numeric identity is sent out. If other EPC tags are being
used the default output is the EPC data. The data is followed by CR+LF ('\r''\n').
A TAGP connection can be initiated by sending the HELOTAGP message to the reader. The TAGP
connection is terminated with the QUIT message.
TX+
Transmitted data to host (See Figure 15 for details)
TX-
Transmitted data to host
GND
Signal ground #3
RX+
Received data from host
RX -
Received data from host
- / 1000 m
The cable for the RS485 interface must be a twisted pair cable and
conform to the EIA RS485 standard.
115.2 kb/s (default)
13-111 02, 2014-RO-012, 2014-04-30