Ethernet

The XT-1 has a built in 10 Mbps/100 Mbps Ethernet switch and dual ports. This makes it possible to connect
a number of readers in a system without the need for additional network equipment. The two ports A and B
are using RJ45 connectors and are fully equivalent.
Figure 13 Ethernet connection, overview and detail
The XT-1 supports auto crossover (Auto-MDIX) so that installation can be done using both patch and
crossover cables. The connectors have eight pins and the wire scheme is based on the T568A standard. The
interfaces have separate isolation of 1500 VDC.
The default IP address of the device is unique among XT-1 readers and can be found on the label on the
back of the XT-1. This makes it possible to create a stand-alone network without changing any reader network
settings. Detailed network settings are configured in firmware, see §4.2.3.3.1. Each port has two LED
indicators for Link/Activity (Yellow/Flashing Yellow) and 10 Mbps/100 Mbps speed (Off/Green).
Connections
Recommended / Max length
Wire size
Table 6 Ethernet connection overview
Ethernet communication is normally done using TagMaster protocol TAGP available at port 9999, see [2]
for details.
A
Port A (See Figure 13 for details)
B
Port B
- / 100 m
CAT5e cable or better is required for the Ethernet connection