THE FORCE/2
T roubleshooting Cont.
Problem
Likely Cause
Blower does not
Loose wire in electrical
operate or variable
system.
speed does operate.
Worn brushes in blower motor Have the brushes inspected
Inline fuse blown.
Agitator trips circuit
Low voltage 99-104v.
breaker at main
panel.
Incorrect size extension cord. For an additional 50' run,
Pushing down on material
in hopper.
Wet insulation material in
hopper.
Worn or frozen airlock
bearing.
Blower trips circuit
Low voltage.
breaker at power
source.
Incorrect extension cord.
Operator in attic
Static electricity from
keeps getting
insulation.
shocked.
Remedy
Have the system inspected
and repaired by a
qualified service center.
and replaced by a
qualified service center.
Turn machine upside
down. Locate fuse holder
on electrical box. Remove
blown fuse and replace
with 15 amp AG style fuse.
FORCE/2 requires a
minimum of 20 amps
@ 115V. Relocate power
cord to a dedicated 20
amp circuit.
use 10/3 cord. For a 100'
run use 8/3 cord.
Do not push down on
insulation while filling hopper.
Do not use wet
material. Disconnect
electrical power and
remove wet material.
Have bearing checked and
replaced by a qualified
technician.
Blower requires a minimum
of 20 amps @ 115V. Use a
dedicated refrigerator outlet
or equivalent.
For an additional 50'
run, use 10/3 cord. For
a 100' run use 8/3 cord.
Mix half-and-half solution
of water and fabric softener.
Mist into insulation while
loading hopper. Note:
Excess moisture will cause
jamming.