THE FORCE/2
T roubleshooting Cont.
Problem
Likely Cause
Machine does not run
Main panel circuit
Cont.
breaker tripped.
Air, but no material,
Slide gate closed.
comes out of hose
Bridging (air pocket
in hopper).
Remote rocker switch for
agitator motor has failed.
Circuit breaker tripped
on main panel.
Jam between blade of
agitator and airlock.
Blower power cord is not
plugged in at main panel
or power cord does not
have electrical power at
source.
Start up capacitor blown
on agitator motor.
Blower does not
Variable speed bypass
operate or variable
switch is in the neutral
speed does operate.
position.
Blower rocker switch on
main panel is "off".
Remote rocker switch for
blower motor has failed.
Loose power cord/extension
cord at electrical system.
Remedy
Wait for a few minutes,
push to reset.
Open to operating
position.
Turn machine "off" and
disconnect from electrical
power. Redistribute material
in hopper. Reconnect to
electrical power.
Replace with original
factory part.
Push to reset.
Disconnect electrical power.
Remove insulation material
from hopper. Locate jam and
remove material with pliers.
Check connection on power
cord at main panel or
make sure electricity is
present at power
source.
Have capacitor replaced by
a qualified service center.
Position the variable speed
bypass toggle switch to either
the "on" or "o position. If
the switch is located in
between the on/off text, it is
in the neutral position and the
blower will not operate.
Switch rocker to "on",use
remote box to operate.
Replace with original
factory part.
Check condition of
electrical plug blades.
27