Motor Driving By Test Operation - Mitsubishi Electric Melservo MR-J5-A User Manual

Ac servo system
Table of Contents

Advertisement

Motor driving by test operation

JOG operation
The JOG operation can be performed when there is no command from the controller. The motor can be operated at the
specified speed. Operate the motor using the JOG Mode screen of MR Configurator2.
(1)
(2)
(3)
■Motor operation setting (1)
Set the motor speed and acceleration/deceleration time constants for JOG operation. When changing the speed to the
permissible speed, set the speed in [Pr. PA28.4 Speed range limit selection].
■Limit switch automatic ON (2)
JOG operation can be performed when the limit switch is not connected. Be sure to avoid causing a collision while performing
the operation.
■Operation (3)
The servo motor can be started (CCW/CW), paused, stopped, or forcibly stopped. Clicking "Start" starts the operation.
When "Rotation only while the CCW or CW button is being pushed" is selected, clicking "Forward CCW" or "Reverse CW" will
perform operation until "Stop" or "Forced Stop" is clicked.
4 STARTUP
58
4.5 Test operation

Advertisement

Table of Contents
loading

Table of Contents