Air Line; Fluid Outlet Line - Graco SaniForce 2150 Operation Manual

Electric-operated diaphragm pump
Hide thumbs Also See for SaniForce 2150:
Table of Contents

Advertisement

Air Line

Line
Air
Air
Line
Models
Models that
Models
that
that Include
Include a a a Compressor:
Include
Compressor:
Compressor:
An air line is already connected from the compressor
to the pump air inlet.
Using Your
Your Own
Own Compressor:
Compressor:
Using
Using
Your
Own
Compressor:
Install a grounded, flexible air hose from the
compressor to the pump air inlet (E).
Using Shop
Shop Air:
Air:
Using
Using
Shop
Air:
1. Install an air filter/regulator assembly (H). The
fluid stall pressure will be the same as the setting
of the air regulator. The filter removes harmful
dirt and moisture from the compressed air supply.
Trapped air can cause the pump to cycle
unexpectedly, which could result in serious
injury from splashing.
3A5132K
2. Locate a master air valve (J) upstream from the
regulator (H). Use it to isolate the system during
cleaning and repair.
3. Locate a bleed-type master air valve (G) close to
the pump and use it to relieve trapped air. Be
sure the valve is easily accessible from the pump
and located downstream from the regulator (H).
4. Install a grounded, flexible air hose (F) between
the accessories and the pump air inlet.
Fluid Outlet
Outlet Line
Line
Fluid
Fluid
Outlet
Line
1. Use flexible, grounded fluid hoses.
2. For best sealing results, use a standard tri-clamp
or DIN style sanitary gasket of a flexible material
such as EPDM, Buna-N, fluoroelastomer, or
silicon.
3. Install a fluid drain valve (L) near the fluid outlet.
4. Install a shutoff valve (M) in the fluid outlet line.
Installation
15