3. Installation

3.1 Overview

This chapter contains information about calculating the safety distance and properly mounting a safety light curtain. Mirror
information is also provided.
FULL REVOLUTION MECHANICAL POWER PRESSES CANNOT BE STOPPED IN MID-STROKE (OSHA 29CFR 1910.217).
• DO NOT use FF-SYA Series light curtains on full revolution mechanical power presses.
Failure to comply with these instructions will result in death or serious injury.
IMPROPER INSTALLATION OF FF-SYA SERIES LIGHT CURTAIN
• Install FF-SYA Light Curtains in accordance with this installation manual and applicable local safety regulations (OSHA, ANSI,
European standards).
• Allow entry into protected area by interruption of sensing field or other safeguarding device only.
Failure to comply with these instructions could result in death or serious injury.
IMPROPER SYSTEM PERFORMANCE
• Comply with local safety requirements when designing machine control link, interface and all control elements that affect
safety.
• Install two independent safety relay contacts into machine control stop circuit. These safety relays shall be cross-monitored to
ensure static safety operation
• Ensure two independent stop circuit safety relays have mechanically linked contacts to reliably detect a welded contact.
• Using the FF-SRS59392 safety relay module will provide static safety contacts to the machine control stop circuit.
Failure to comply with these instructions could result in death or serious injury.
IMPROPER MACHINE REACTION
• Ensure the machine control is capable of stopping the machine at any point in the cycle.
• Ensure that a loss of power does NOT impair stopping action of machine.
Failure to comply with these instructions could result in death or serious injury.

3.2 Point-of-operation Guarding

IMPROPER POINT-OF-OPERATION INSTALLATION.
• Do NOT use the FF-SYA234 multibeam systems or the FF-SYA60 light curtains for point-of-operation guarding. Use the
FF-SYA14 or FF-SYA30 light curtains only.
• DO NOT allow an operator to stand undetected between the light curtain and the machine when using FF-SYA Series safety
light curtains for point-of-operation guarding.
Failure to comply with these instructions will result in death or serious injury.
Point-of-operation is defined as that area where a machine performs work (such as cutting, shaping, boring, or forming) on a
material. For point-of-operation guarding the FF-SYA14 and FF-SYA30 safety light curtain(s) and any mechanical guards must
be installed so no one can stand undetected between the light curtain and the dangerous machine zone. Additional hard
guarding, interlocked guarding, light curtain, safety mats or safety scanners may be required.

3.3 Perimeter Guarding

IMPROPER INSTALLATION OF FF-SYA SERIES PERIMETER DEVICE
• Install the FF-SYA234 multibeam systems or the FF-SYA60 light curtain in accordance with this installation manual and
applicable safety regulations and standards (OSHA, ANSI, European standards).
• Only allow entry into protected area by interruption of sensing field or other safeguarding device.
Failure to comply with these instructions could result in death or serious injury.