Honeywell Miller Soll Xenon Assembly, Installation And Operating Instructions

Honeywell Miller Soll Xenon Assembly, Installation And Operating Instructions

Anchor device

Advertisement

Quick Links

Assembly, installation and operating
instructions for
Söll Xenon anchor device
According to EN 795:2012 and CEN/TS 16415:2012
(The following must be completed by the installer in permanent waterproof ink.)
Date of manufacture: ....................................................................................
Date of initial operation: ................................................................................
Operator/User: ..............................................................................................
Street: ...........................................................................................................
Place:............................................................................................................
Tel.: ...................................................... Fax: ...............................................
www.fall-protection.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Miller Soll Xenon

  • Page 1 Assembly, installation and operating instructions for Söll Xenon anchor device According to EN 795:2012 and CEN/TS 16415:2012 (The following must be completed by the installer in permanent waterproof ink.) Date of manufacture: ..................Date of initial operation: ................Operator/User: ....................Street: ......................
  • Page 2: Table Of Contents

    Content 1 Introduction ...................4 1.1 Product description ...............4 1.2 General information and safety precautions .........4 1.3 Limitations, capabilities and performance ........5 2 Inspection and assembly before use ..........6 2.1 Inspection before installation ............6 2.2 Compatibilities ................7 2.3 Prior use checks ................8 3 Use ....................
  • Page 3 Explanation of symbols Danger! Improper or careless handling could cause accidents leading to falls or even death. Warning! Non-observance could result in serious injury. Important! Useful information and user tips are given here. Changes in this issue: - These instructions are protected by copyright! They may not be reproduced and distributed in any way/ by any means without prior written consent of the author according to Articles 16 and 17 of the German Copyright Act.
  • Page 4: Introduction

    1 Introduction 1.1 Product description This manual relates to the Söll XENON anchor device. The complete list of the product reference is available at you installer or your responsible customer service. (see. 5.2 contact). The Söll XENON anchor device is a horizontal lifeline system with a maximum incline of 15° which persons against falls from height and simultaneously provides them with a great freedom of move- ment.
  • Page 5: Limitations, Capabilities And Performance

    (SPERIAN FALL PROTECTION Deutschland GmbH & Co. KG or one of its authorised dealers). Prevailing accident prevention regulations and safety guidelines must be followed. operating instructions of the respective companies and the instructions for use/user information provided by the relevant manufacturer must be followed. The Söll Xenon anchor device should only be used for the intended purpose, e.g.
  • Page 6: Inspection And Assembly Before Use

    2 Inspection and assembly before use 2.1 Inspection before installation Warning! must check whether the components on which the Söll Xenon anchor device is to be stability). Manufacturer’s installation instructions and installation suggestions as per the EN 795 standard and Australian Standard AS/NZS 1891.4 must be followed at the time of installation.
  • Page 7: Compatibilities

    Calculation of the Necessary Fall Clearance: + Lanyard length LL + Lanyard energy absorber deployment DLAbs + User height t (usually 6 feet / 1.80 m) – Line height H + Safety distance 1m = Necessary Fall Clearance NFC 2.2 Compatibilities All system components are designed to be used in a Söll XENON anchor device only.
  • Page 8: Prior Use Checks

    2.3 Prior use checks Ensure that the Söll-Xenon anchor device is inspected before each use. The anchor device must be in perfect working condition and must be functioning properly before and during every use of the device. Ensure that the device and the components are not deformed or damaged. The Söll-Xenon anchor device should not be used if the following defects are detected: 4.0 mm (standard shuttle) or (Overhead...
  • Page 9 ting the ground or any other obstacles in the event of a fall. re using the Söll-Xenon anchor device. when the third ring of the pre-tension indicator becomes visible. Pre-tension ~ 0.8 kN Pre-tension ~ 2 kN Pre-tension too low Pre-tension too high standard systems) Overhead systems only -...
  • Page 10: Use

    3 Use 3.1 Forseable misuse Every user must use a separate shuttle! Only the shuttles approved by the manufacturer should be used. Danger! Be careful when using self-retractable lifelines which have not been tested in combination with the horizontal anchor device. A swinging cable in case of a fall can affect the blocking function of the self-retractable lifeline in certain circumstances.
  • Page 11: Use Of The Overhead Roller Shuttle

    Fig. 3.4 Fig. 3.2 Caution! Half-shells of the shuttle must shut when the anchor eye is pulled! To detach the shuttle after use press the unlock key (2) and push the ancho- Danger! The shuttle or the carabiner of the lanyard may be detached only if the user is secured otherwise against falling from height! 3.3 Use of the overhead roller shuttle lanyard into the anchoring eye (1) of the overhead roller shuttle, similarly to the standard shuttle.
  • Page 12: Emergency Procedures

    Danger! The green marking ring on the unlock key MUST be visible. Only then the shuttle is lok- Note: If the horizontal anchor system has intermediate brackets or curves, it must be ensured Fig. 3.13 Fig. 3.14 3.4 Emergency procedures It is essential that the owner of this system has a rescue plan, wherein all possible emergencies, in particular the urgent need to evacuate an injured person, that may occur while working are taken into account.
  • Page 13: After Use Information And Maintenance

    4 After use information and maintenance 4.1 Repair Only the manufacturer or a person appointed by the manufacturer is allowed to carry out repairs. Components with mechanical damages (e.g. resulting from a fall) must be replaced! Only use original spare parts or the ones approved by the manufacturer while carrying out repairs. For further information on the availability and suitability of spare parts, please refer to our Söll XENON Information Guide or contact your installer or alternatively, contact the customer service person re- sponsible for your area.
  • Page 14: Regular Inspections

    4.3 Regular inspections Further inspections should be carried out in accordance with the inspection list below: Fig. 4.1 Fig. 4.2 Fig. 4.3 Cable tension! The green ring on the energy absorber must be visible, - if the red ring shows the tension is excessive.
  • Page 15: Cleaning, Transportation And Storage

    Check intermediate hangers and bends: - there must be no plastic deformation, - presence and intactness of the plastic guides (depending on type), check if the nuts or screws are tightly screwed on, if any deformation is visible on the bend and also check the cable tensi- on on both sides of the bend! Condition of the standard and overhead shuttle: The shuttle and especially its movable com- ponents (rollers, locking pin, locking plate, half shells unlock key, etc.), must be clean and work...
  • Page 16: Miscellaneous

    The pre- Manufacturer, vendor or importer Type designation: Söll XENON Max. number of users Max. length of PPE Next inspection date Installation number (Labeled internally by the installer if necessary) Number of absorbers Length of the system Pictograph that indicates to a user that the instructions for use should be read: Note: Installer contact details Number and year of the European standard: EN 795:2012...
  • Page 17: Contact

    5.3: overhead roller shuttle): Type designation: Söll XENON Year of manufacture Serial number (SN) Number and year of the European standard ment: CE158 Pictograph indication that the user should read the instructions for use: For Southern Europe: System Customer Service (Vierzon, France) For Northern Europe: System Customer Service (Hof, Germany) www.fall-protection.com...
  • Page 18 Inspections and repairs Year of manufacture: Type designations/standard: Date of purchase: Serial number: Date Reason for Damage determined, repairs Name and signa- Date of the next working on the carried out and other impor- ture of the expert regular inspec- system (*) tant details tion...
  • Page 19 Further remarks www.fall-protection.com...
  • Page 20 Sperian Fall Protection Deutschland GmbH & Co. KG SE 94 Seligenweg 10 February 2013 D-95028 Hof Phone +49 (0) 9281 83 02 0 © 2013 Honeywell International Inc. Fax +49 (0) 9281 36 26 www.fall-protection.com...

Table of Contents