Installation and Setup
The Remote Setup Wizard has the following requirements:
•
Computer running Windows XP or a higher version.
•
Connection between the array and computer. There are two options:
–
Connect the computer to the same Ethernet segment as the array, and
make sure that Layer 2 multicasting is not blocked between the array and
the computer.
–
Use an RJ45 network cable to connect the computer to Ethernet 0 on the
array's active control module (ACT LED will be green).
About the setup Utility
The
utility is an interactive, command line utility that prompts for
setup
information about the array and group configuration.
To use the
utility, you must have a serial connection between the array and
setup
a console terminal or a computer running a terminal emulator.
After choosing a method, collect the information needed for the array
configuration.
Step 2: Collect Configuration Information
Regardless of the method you use to configure the software, you must collect the
information in Table 3-1 and Table 3-2. Obtain IP addresses from your network
administrator, as needed.
Also, make sure you follow the network recommendations in Table 2-1.
Prompt
Description
Member name
Unique name for the array in the group (63 or fewer letters, numbers,
or hyphens). First character must be a letter or number.
Network interface Name of an array network interface (
that is connected to a functioning port on a network switch.
3–2
Table 3-1: Array Configuration
Software Configuration
,
,
, or eth3)
eth0
eth1
eth2