Environmental Requirements - Dell EqualLogic PS Series Installation And Setup Manual

Storage arrays
Hide thumbs Also See for EqualLogic PS Series:
Table of Contents

Advertisement

Installation and Setup

Environmental Requirements

You must meet these environmental requirements for a PS6000 array:
Only operate an enclosure from a power source with a voltage range of 100 to
240 VAC.
Make sure each power source has sufficient electrical overload protection.
Make sure there is sufficient space for air flow in front of and behind the
array.
Make sure the location is properly vented.
Review the technical specifications in Table 2-2 to make sure your
environment supports its requirements.
Table 2-2: PS6000 Technical Specifications
Component
Weight of fully-loaded array
Operating temperature
Storage temperature
Operating altitude
Operational relative humidity
Thermal output (fully-loaded array) 1700 BTU/hour (SAS disks)
Operational shock
Operational vibration
Input voltage
Input frequency
System input power
Each power supply
Dimensions
Requirement
77.6 pounds or 35 kilograms
41 to 95 degrees F / 5 to 35 degrees C
-22 to 140 degrees F / -30 to 60 degrees C
10,000 feet (3048 meters)
20 to 80 percent non-condensing
1550 BTU/hour (SATA disks)
5 G for 10 ms 1/2 sin
Random 0.21grms 5 - 500 Hz
100 to 240 VAC (auto-sensing)
48 - 62 Hz
530 VA (maximum)
450 watts DC output
Maximum input power: 0.7 KVA
Input current: 7 – 3.5A
5.12 in. x 19 in. x 21.7 in.
(13 cm x 48.26 cm x 55.1 cm)
Installing a PS6000 Array
2–5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Equallogic ps6000Equallogic ps6500

Table of Contents