A Environmental, Power, And Other Specifications - Dell EqualLogic PS4000 Hardware Maintenance

Storage arrays
Hide thumbs Also See for EqualLogic PS4000:
Table of Contents

Advertisement

A Environmental, Power, and Other Specifications

Table A-2 describes the environmental, power, and physical specifications for a
PS4000 array.
Table A-2: PS4000 Array Specifications
Component
Weight of fully-loaded array
Operating temperature
Storage temperature
Maximum operating altitude
Operational relative humidity
Storage relative humidity
Thermal output (fully-loaded array) 1700 BTU/hour (SAS disks)
Operational shock
Operational vibration
Input voltage
Input frequency
System input power
Each power supply
Chassis dimensions
Requirement
35 kg (77.6 lb)
5 to 35 °C (41 to 95 °F)
-30 to 60 °C (-22 to 140 °F)
3048 meters (10,000 feet)
20% to 80% noncondensing
5% to 80% noncondensing
1550 BTU/hour (SATA disks)
5g peak 1/2 sin, for 10ms
.21 G
5 to 500 Hz Random
rms
100 to 240 VAC (auto-sensing)
48 - 62 Hz
530 VA (maximum)
450 watts DC output
Maximum input power: 0.7 KVA
Input current: 7 – 3.5A
13 cm by 48.26 cm by 55.1 cm
(5.12 in. by 19 in. by 21.7 in.)
A–1

Hide quick links:

Advertisement

Table of Contents
loading