Page 2
HTU418B Specifications Diagrams HTU418B-400/…-M12 Ultrasonic specifications HTU418B-400/4T4… HTU418B-1300/4T4… Typ. response behavior (plate 20x20mm) Scanning range 25 … 400mm 150 … 1300mm Adjustment range 25 … 400mm 150 … 1300mm Ultrasonic frequency 310kHz 200kHz Typ. opening angle 9° 16° Resolution switching output 0.5mm Direction of beam axial...
Page 3
The sensors listed here are preferred types; current information at www.leuze.com. Designation Part no. Scanning range 25 … 400mm HTU418B-400/4T4-M12 50124268 150 … 1300mm HTU418B-1300/4T4-M12 50124272 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 HTU418B-…/4T4-M12 - 05 info@leuze.com • www.leuze.com...
Page 4
HTU418B Device functions and indicators All sensor settings are taught via the Teach-IN input. Device status and switching states are indicated by a green and a yellow LED as follows: NO contact switching behavior NC contact switching behavior Switching point Switching point OUT active OUT not active...