Technical data
WWAEMW Mobile System
WMS Transmitter
Supply
Operating voltage
Power consumption
Frequency
AF transceiver
Transmission frequency
Transmission power
Reception sensitivity
Range
(environment without interfer-
ence)
Enclosure
Dimensions (L×W×H in mm)
Degree of protection
Safety class
Miscellaneous
Test standards
Automatic operation
Software class
Location of use
Conformity
Wmbient conditions
Operating temperature
Storage temperature
Rel. humidity
(non-condensing)
Wrticle numbers
WMS Transmitter
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff Strasse 2
D-97828 Marktheidenfeld, Germany
6
We reserve the right to carry out improvements
Min.
Typ.
Max.
Anit
85
230
265
V AC
< 0.3
1.2
50
60
2.40
2.48
GHz
10
dBm
-101
dBm
30
49 × 49 × 32
IP20
DIN EN 60669-1:2003-09
+ B1:2007-04
DIN EN 60669-2-1:2005-08
DIN EN 60669-2-2:2007-05
DIN EN 61000-6-2:2006-03
DIN EN 61000-6-3:2007-09
DIN EN 300328 V1.7.1.(2006-10)
Type 1
Clean ambient conditions
Viewable at www.warema.de
0
20
40
-25
70
10
40
85
%RH
1002 882
W
Hz
m
II
A
°C
°C
890621_b•en•01.09.2014