Replacing The Seat And Plug; Replacing The Operating Diaphragm - Samson 41-23 Mounting And Operating Instructions

Universal pressure reducing valve self-operated pressure regulators
Table of Contents

Advertisement

9.3.3
Replacing the seat and
plug
To replace seat and plug, contact
SAMSON's After-sales Service.
Further information is available in the the
Annex.
9.3.4
Replacing the operating
diaphragm
NOTICE
!
Do not exchange the operating diaphragm
in an FDA-compliant regulator version.
SAMSON's After-sales Service can support
you to perform such service work.
Note
There are no spare parts available for the
bellows actuators. The entire actuator must
be replaced if it is defective.
Tip
The associated order number is written on
the actual operating diaphragm.
EB 2512 EN
Î Refer to Fig. 9-1
Removing the operating diaphragm
1. Put the regulator out of operation (see
the 'Decommissioning' section).
2. Completely relieve the tension from the
set point springs (7) by turning the set
point adjuster (6) counterclockwise ().
WARNING
WARNING
!
!
Stored energy in the set point springs can
cause components to move in an uncon-
trolled manner resulting in injury to hands or
fingers.
3. Unscrew the control line (17).
4. Unscrew the nuts (9) and remove the ac-
tuator.
5. Clamp the actuator stem (11) into a suit-
able fixture. Mark the side of the actua-
tor to avoid reassembling it the wrong
way.
6. Unscrew nuts and bolts (15) from the ac-
tuator. Remove the actuator case with
control line connection (16).
7. Unscrew the diaphragm plate nut (14)
and remove the operating diaphragm
(12) from the diaphragm plate (13).