Replacing The Seat And Plug; Replacing The Actuator's Operating Diaphragm - Samson 42-36 Mounting And Operating Instructions

Flow regulator self-operated regulators
Table of Contents

Advertisement

9.3.2
Replacing the seat and
plug
To replace seat and plug, contact
SAMSON's After-sales Service.
Further information is available in Annex
('After-sales service').
EB 3015 EN
9.3.3
Replacing the actuator's
operating diaphragm
NOTICE
!
Do not exchange the operating diaphragm
in an FDA-compliant regulator version.
SAMSON's After-sales Service can support
you to perform such service work.
Tip
The associated order number is written on
the actual operating diaphragm.
Î See Fig. 9-1 and Fig. 9-2
Removing the operating diaphragm
1. Put the regulator out of operation (see
the 'Decommissioning' section).
2. Unscrew the control line (17).
3. Unscrew the coupling nut (11) of the dia-
phragm actuator from the valve. Remove
the actuator.
4. Clamp the coupling nut (11) into a suit-
able fixture.
5. Unscrew nuts and bolts (15) from the ac-
tuator. Remove the actuator case.
6. Unscrew the diaphragm plate nut (17)
and remove the operating diaphragm
(12) from the diaphragm plate (16).
Servicing
9-7

Advertisement