Powering Dv-Dosc; Table 3: Dv-Dosc Power Handling And Recommended Power Amplifier Ratings - L-Acoustics dV-DOSC Operator's Manual

Hide thumbs Also See for dV-DOSC:
Table of Contents

Advertisement

1.6 POWERING dV-DOSC

L-ACOUSTICS LA24a or LA48a power amplifiers are specified for use with dV-DOSC. For full
technical details please see the LA24a or LA48a user manuals (available for download on:
acoustics.com). Both amplifiers have 32 dB gain and the input sensitivities are 1.95 Vrms (8.0 dBu) and
2.3 Vrms (9.5 dBu) for the LA24a and LA48a, respectively.
dV-DOSC is an active 2-way enclosure and the load ratings are as follows:
1 x 8 ohms high section
1 x 8 ohms low section (2 x 16 ohm 8" components connected in parallel)
According to standard L-ACOUSTICS specification practice, minimum power amplifier output ratings
are defined as twice the RMS power rating for the low section and equal to the peak power rating for
the high section. Power handling for dV-DOSC (single and multiple enclosures in parallel) and
recommended power amplifier ratings are summarized in Table 3.

Table 3: dV-DOSC Power Handling and Recommended Power Amplifier Ratings

ONE dV-DOSC
SECTION
LOAD
RMS
dV LOW
8
380
dV HIGH
8
dV-DOSC LOW SECTION
REC'D POWER
LOAD
REC'D
(ohms)
POWER
2.7
2280
4
1520
8
760
Note: Power handling for the dV-DOSC low section depends on the selected high pass filter frequency for a
given preset (80 Hz, 100 Hz, 120 or 200 Hz). Limiter settings are adjusted in the OEM factory presets to
account for this.
As seen in Table 3, the LA24a is suitable for powering up to 2 dV-DOSC while the LA48a is
recommended for powering 3 enclosures in parallel. Tables 4 and 5 give a cross reference of L-
ACOUSTICS LA24a and LA48a power amplifier ratings and MLS switch settings for powering dV-
DOSC. For system protection via power matching, recommended MLS switch settings are indicated
in bold italics and bold for the low and high sections, respectively. For touring applications, LA24a and
LA48a amplifiers can be operated with MLS switches in the 0 dB position and system protection
provided by OEM factory preset limiter settings which are calibrated to 2x the RMS power handling
for each section. For fixed installations it is recommended that the MLS switch settings tabulated in
Tables 4 and 5 are used.
When the L-ACOUSTICS RK124a is equipped with 4 L-ACOUSTICS LA48a power amplifiers, a single
power amplifier rack can power: 3+3+3+3 dV-DOSC, 4+4 dV-SUB or SB218, 8+8 SB118.
dV-DOSC dV-SUB Manual V3.0
TWO dV-DOSC
PEAK
REC'D
LOAD
1520
760
66
260
260
AMPLIFIER OUTPUT POWER
(MLS SETTING)
LA 17a
LA 24a
LA 48a
1080
1635
2130
do not use
(0 dB)
(-2 dB)
840
1500
1600
do not use
(0 dB)
(-2 dB)
430
1100
820
do not use
(0 dB)
(-2 dB)
RMS
PEAK
REC'D
4
760
3040
1520
4
130
520
dV-DOSC HI SECTION
REC'D POWER
LOAD
REC'D
(ohms)
POWER
2.7
800
4
520
8
260
June 2005
THREE dV-DOSC
LOAD
RMS
2.7
1140
520
2.7
200
AMPLIFIER OUTPUT POWER
(MLS SETTING)
LA 17a
LA 24a
1080
1000
(0 dB)
(-5 dB)
840
600
(0 dB)
(-5 dB)
430
300
(0 dB)
(-5 dB)
37
www.l-
PEAK
REC'D
4560
2280
800
800
LA 48a
1380
(-5 dB)
830
(-5 dB)
430
(-5 dB)

Hide quick links: