SIGNAL DISTRIBUTION AND CABLING

CO6 CONTROL OUTPUT PANEL
Control Output Panel for use with a single 2 in x 6 out (or 3 x 6) digital signal processor (DSP) to
create a compact, modular drive rack or for mounting in RK12U amplifier racks along with amplifiers
and a DSP unit for standalone master rack packaging. DSP outputs are connected to the 6x female
XLR patch bay on the rear side of the CO6 panel and then assigned to the front panel 19-pin CACOM
connector to provide a 6 channel multi-conductor return snake system when used with DOM30
Cross Link cables.
CO24 CONTROL OUTPUT PANEL
Control Output Panel for use with four 2 in x 6 out (or 3 x 6) DSPs to create a system drive rack: 1x
84 pin MASS connector; 4x 19 pin male CA-COM connectors; 24x female XLR inputs on the internal
side; 1x male/female 4-pin XLR pair for amplifier remote control/monitoring. Used for connecting
DSP outputs and amplifier remote control/monitoring to MC28100 MULTI return snake lines.
MD24 MULTI DISTRO PANEL
Stage distribution panel with 1x 84 pin MASS connector (for connection of MULTI return snake from
FOH), 4x 19 pin male CA-COM (for distribution of Left-Left, Left, Right, Right-Right signal lines), 1x
male/female 4-pin XLR pair (for distribution of amplifier remote control).
MC28100 MULTI-CONDUCTOR CABLE
24 pair multi-conductor return snake, 100 m (325 ft) length, fitted with 84 pin MASS connectors at
each end (used for connecting CONTROL OUTPUT panel, typically located at FOH, to MULTI
DISTRO panel for signal distribution to the amplifier racks)
PCMCIA CARDS
Contain OEM factory preset data for programming DSP units (PCM224D, PCM226D and PCM366D
for XTA DP224, DP226 and BSS 366, respectively). Other approved DSPs are programmed via
computer download of preset data (Lake Contour, BSS Soundweb).
DOM2 AMP LINK CABLE
6 pair multi-conductor cable, 2 m (6.5 ft) length, with 2x female 19 pin bayonet CA-COM connectors
(for distributing signal from CO6 or MD24 panels to amplifier racks and linking amplifier racks)
DOM30 CROSS LINK CABLE
6 pair multi-conductor cable, 30 m (100 ft) length, with 2x female 19 pin bayonet CA-COM
connectors (for cross-stage connection from the MD24 panel to amplifier racks or for use as a return
snake for smaller system configurations)
DOMP ADAPTER
19 pin male/male CA-COM adapter (for connecting two AMP LINK or CROSS LINK cables when
longer lengths are required)
DOMM LINK BREAKOUT
Multipair cable adapter with 1x female 19 pin CA-COM connector at one end, 6x male XLR
connectors at the other (used as a LINK cable breakout for patching and testing purposes)
DOMF LINK-BREAKOUT
Multipair cable adapter with 1x female 19 pin CA-COM connector at one end, 6x female XLR
connectors at the other (used as a LINK cable breakout for patching and testing purposes).
Note: Parts nomenclature is as follows:
DOM = DOSC Modulation
DOMP = DOSC Modulation Prolongateur (french for extender)
dV-DOSC dV-SUB Manual V3.0
June 2005