APPENDIX B - MAINTENANCE

All major components requiring maintenance have guidelines listed in the respective operation manuals. Refer
to those individual operation manuals for other preventative maintenance and regular maintenance information.
Maintenance Table
COMPONENT
Compressed Air Filter
Compressed Air Filter
Water Chiller Filter
Dissolved Ozone Sensor
Dissolved Ozone Sensor
Ozone Leak Sensor
ORP Sensor if equipped
Check Valve-High PSI
Check Valve-Low PSI
Destruct Unit
Oxygen Concentrator
Injection Pump-3/4hp.
16
/
WZ SERIES
ACTION
Replace the filter element 3 months/as needed PR-8: Replacement filter
Replace the filter element 3 months/as needed CF-8: Repl. Filter
Replace the filter element 3 months/as needed Ecopure EPW2C Filters
Replace the Electrolyte
Replace the flat cap
Replace the sensor
Replace the sensor
Replace
Replace
Replace the Catalyst
Replace the O2 module
Replace/rebuild pump
TIME INTERVAL
6 months, dependant
on water quality
1 year
1 year
1 year
1 year
1 year
1 year
2-5 years
3-5 years
PART NUMBER(S)
AS-500 Electrolyte
AS– Membrane Cap Flat
OEM-3: RME-1.0
ORP-Sensor
CVHP-8
CVLP-4
ODS-Catalyst
ATF-23
CM5-G-3 Rebuild (exchange
pumps)