Introduction: OZV-20DG ozone generator can not operate on dry air feed gas, it
is designed and it can operate solely on oxygen sources that are capable of supply of
5 LPM (10 SCFH) of oxygen flow.
1.
INSTALLATION CONCERNS.
A.1.
Ozone is a very strong oxidant. Only ozone resistant materials may be used in
contact with ozone gas.
A.2.
Oxygen generators release moisture and nitrogen gas into the ozone room. In
addition also tiny amounts of ozone are generated around the high voltage
terminals. Both will accumulate over a time, exceeding the specified level of 85%
R.H. or 0.08 ppm of ozone, and cause the equipment failure. Proper ventilation is
essential. In many states proper ventilation is required by law. The rate of
ventilation must be at least 3 m
A.3.
The air for the ozone room must be free of dust, oil, acid and other volatile
vapors. All these elements would otherwise shorten the life of the high voltage
circuits. Also the oxygen generator would be disabled very fast, namely from oil
vapors. Oil vapors may be present where a backup power generator is in place.
A.4.
The equipment must be protected from splashing water, rain, sun, mist and
Relative Humidity above 85%. For the best performance the temperature
must not exceed 30
system to decrease R.H. and temperature below the above levels.
A.5.
The ozone generator must be protected from vacuum airlock
B.
INSTALLATION.
B.1.
Install screws onto the wall, or onto a designer-frame and hook-up the ozone
generator. Allow for easy access to the bottom back for connecting the tubes, to
the right site for the cooling-air intake, and to the left side for the cooling air
discharge.
B.2.
Every ozone system must be equipped with vacuum-breaking Balance
Barometer, installed between the ozone generator and vacuum-source MIC
Ozone Solutions, Inc
Advanced Ozone Technology
OZV-20DG OZONE GENERATOR
3
/min (120 CFM).
°
C. Install a small A/C unit in-line with the air ventilation
November 19, 2007

Advertisement

loading

Summary of Contents for Ozone Solutions OZV-20DG

  • Page 1 INSTALLATION MANUAL OZV-20DG OZONE GENERATOR Introduction: OZV-20DG ozone generator can not operate on dry air feed gas, it is designed and it can operate solely on oxygen sources that are capable of supply of 5 LPM (10 SCFH) of oxygen flow.
  • Page 2 injector. With Teflon-lined ¼” I.D. tubing connect the lower fitting at the BBL to the stainless steel valve at the injector. Secure all connections with s. s. clamps and keep the valve closed for now. With Teflon-lined ¼” I.D. tubing connect the top fitting at the BBL to the OZONE Kynar fitting at the bottom of the ozone generator-ask AZCO for details.
  • Page 3 C.4. Once the level inside the BBL is balanced and the flowmeter reads 5 LPM, plug- in the ozone generator to the power outlet and start with the main switch. I high- pitch sound will tell the ozone-generating cell inside is active and producing ozone.
  • Page 4 The lamp flashes, . Voltage in the power line is greater than 132V The digital controls will restore the operation once proper operating line-voltage is restored. Please call us if you have any questions. Ozone Solutions, Inc. Hull, IA 712-439-6880 tech@ozonesolutions.com...