Keysight Technologies 16190B Operation And Service Manual
Keysight Technologies 16190B Operation And Service Manual

Keysight Technologies 16190B Operation And Service Manual

Performance test kit

Advertisement

Quick Links

Keysight 16190B Performance Test Kit
Operation and
Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 16190B and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight Technologies 16190B

  • Page 1 Keysight 16190B Performance Test Kit Operation and Service Manual...
  • Page 2 FAR and the DFARS agreement and written consent from used or copied only in accordance and are set forth specifically in Keysight Technologies, Inc. as with the terms of such license. writing elsewhere in the EULA. governed by United States and...
  • Page 3: Table Of Contents

    Keysight Technologies Packing Materials ........
  • Page 4 Contents Keysight 16190B Operation and Service Manual...
  • Page 5: General Information

    This chapter provides the Keysight Technologies 16190B Performance Test Kit description, characteristics and related general information. Description Keysight Technologies 16190B is a performance test kit designed to verify the impedance measurement accuracy of impedance analyzers or impedance meters that have a 7 mm measurement terminal.
  • Page 6: Initial Inspection

    Keysight Technologies office. If the shipping container is damaged, or the cushioning material shows signs of stress, notify the carrier as well as theKeysight Technologies office. Keep the shipping materials for the carrier’s inspection. Keysight 16190B Performance Test Kit...
  • Page 7: Repacking For Shipment

    The following general instructions should be used for re-packing with commercially available packing materials: 1. If shipping to a Keysight Technologies office or service center, attach a tag indicating the type of service required, return address, model number, and full serial number.
  • Page 8: Characteristics

    General Information Characteristics Characteristics This section provides the characteristics of the Keysight 16190B performance test kit. Electrical Characteristic Table 1-2 list the performance test kit electrical characteristics Table 1-2 Electrical Characteristics OPEN Termination 0.63 pF  5% at 1 MHz 50 ...
  • Page 9: Carrying Case Dimensions

    General Information Characteristics Table 1-5 Storage Conditions Altitude 0 m to 15000 m Carrying Case Dimensions The carrying case dimensions are; 350 mm (W) x 100 mm (H) x 270 mm (D) Keysight 16190B Performance Test Kit...
  • Page 10 General Information Characteristics Keysight 16190B Performance Test Kit...
  • Page 11: Operation

    Keysight 16190B Performance Test Kit Operation and Service Manual Operation This chapter provides operating information for theKeysight 16190B Performance Test Kit. Operating Precautions There are several precautions that must be observed to protect the devices in this kit and the instruments being tested.
  • Page 12 (PN 85050-20001). If the inspection shows that the airline center conductor tip needs to be replaced, replace the tip (PN 1250-2006). Do not use damaged connectors. Document “Microwave Connector Care” (PN 08510-90064) explains in detail how to care for microwave connectors. Keysight 16190B Performance Test Kit...
  • Page 13: Cleaning Connectors

    After cleaning, blow the connector dry with a gentle stream of clean compressed air or nitrogen. Always completely dry a connector before you reassemble or use it. 5. Reinspect Inspect the connector again to be sure that no particles or residue. Keysight 16190B Performance Test Kit...
  • Page 14: Making Connection

    Figure 2-1 Lifting out 7mm connector sleeve 2. While pressing terminations from the top as shown inFigure 2-2, firmly connect it to the 7-mm terminal, clockwise viewed from the top Figure 2-2 Termination connection Keysight 16190B Performance Test Kit...
  • Page 15: Connecting Airline And Terminations

    136 N-cm. (A 1/2 inch open end wrench may be necessary to hold the airline stationary.) c. Gently inserts the airline center conductor into termination’s center conductor. Mate the outer conductors. Then torque the connection to 136 N-cm Keysight 16190B Performance Test Kit...
  • Page 16: Calibration Data Diskette Format

    Table 2-1 Diskette Format Outline Media 3.5 inch Double-side Initialize Format ASCII File Bssss.DAT BINARY File 16190Bssss 1. ssss is least 4 digit of the kit’s serial number 2. For backward compatibility of old calibration file. Keysight 16190B Performance Test Kit...
  • Page 17: Service

    Keysight 16190B Performance Test Kit Operation and Service Manual Service In this chapter, maintenance of 16190B is described. Calibration The performance test kit is calibrated when shipped from the factory. The performance test kit must be calibrated at a facility that satisfies the...
  • Page 18 4.0 mrad 6.0 mrad 1300 No Calibration 4.0 mrad 7.0 mrad 7.0 mrad 1600 1800 4.0 mrad 7.0 mrad 7.0 mrad 2000 8.0 mrad 10 mrad 10 mrad 8.0 mrad 10 mrad 2200 No Calibration Keysight 16190B Performance Test Kit...
  • Page 19: Calibration Period

    Repair The performance test kit can be repaired only at Keysight Technologies facilities. For complete information on repair, contact your nearest Keysight Technologies office.
  • Page 20 Service Repair Keysight 16190B Performance Test Kit...
  • Page 21 This information is subject to change without notice. © Keysight Technologies 2000-2017 Edition 4, October 2017 *16190-90020* 16190-90020 www.keysight.com...

Table of Contents