Replacing Fuse - Haug EN 8 SLC MT Operating Instructions Manual

Discharging power pack
Table of Contents

Advertisement

6.1 Replacing fuse

Damage to equipment!
An incorrect fuse in the discharging power pack may cause a defect.
This may result in a cable fire.
• Only use fuses of the specified type.
• Never use repaired fuses.
• Never bridge the fuse.
The unit type and the rated voltage are indicated on the nameplate.
1. Disconnect the discharging
2. Determine and rectify the
3. Use a screwdriver to
4. Replace the fuse and attach
Only use the following fuse:
• 100 V = T500 mA L250; 5 x 20 mm
• 115 V = T500 mA L250; 5 x 20 mm
• 230 V = T250 mA L250; 5 x 20 mm
power pack.
reason for the fuse failure.
unscrew the fuse holder (C)
and remove it.
the fuse holder again.
6
Troubleshooting
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

01.7913.05501.7913.00501.7912.005