Troubleshooting
6 Troubleshooting
Electric shock hazard!
The discharging power pack is operated electrically and generates a
high electric voltage. In the event of any faults, there is a risk of an
electric shock.
• Faults may only be eliminated by a trained and qualified
NOTE:
If the error cannot be removed in this way, return the discharging
power pack and ionizing unit for checking to HAUG GmbH & Co. KG
(the address is provided on the back of the envelope).
Fault
Mains
switch
does not
illuminate.
Ionisation
not
available
Signalling
lamp does
not
illuminate
during
operation.
14
electrician.
Cause
Mains failure
Defective fuse in
discharging power
pack.
No HV
Electrically
conductive
deposits on
ionizing unit.
Discharging power
pack is damaged.
The ionizing system
has a fault.
Troubleshooting
Check mains fuse
Check fuse in discharging power
pack.
Check connections in
discharging power pack.
Clean ionizing unit
Shut the discharging power pack
down immediately and secure
against switching on.
Perform work steps according to
the following flow chart. Refer
page 16..