When the detector is switched on for the first time it needs to be configured for the end application.
Wherever possible this will be carried out by Loma before the unit is dispatched from our factory, or
alternatively, by a LOMA Service Engineer during a commissioning visit. Primarily, this information
is required to optimise machine performance for the application, and to enable certain features that
the user may require.
There are circumstances, however, where it may be necessary for the end user to carry out the
commissioning procedure for the control unit himself. Typically, this would occur when LOMA do
not have enough information about the end application, such as the belt speed or reject details, to
fully configure the machine. There are, in addition, other instances such as performing a software
update, moving the detector to a different application, replacing a control card, etc.. By following
through the step by step configuration guide the unit can easily be set up from scratch as required.
Alternatively, if only small changes are required to the configuration of the machine, then the menu
entries within the Service menu can individually be adjusted.
At the start of this section is a menu map for the Service menu upon which configuration details for
the machine can be recorded. We suggest that you fill this in when you configure the system, so that if
you ever need to repeat the exercise all the information will be ready to hand.
Step One
If the unit is not already at the top of the Configuration menu, displaying the +NOT DETECTING+
warning message, go to this menu position now. If you do not know how to do this, press the
following key sequence:
1
Press the [SETUP] key once.
2
Press the [ ] key until the display shows "SERVICE".
3
Press the [ENTER] key once.
4
Press the [ ] key until the password shows "21".
5
Press the [ENTER] key once. The display should now show "USER OPTIONS".
6
Press the down key three times, so that the display shows "CONFIGURATION".
7
Press the [ENTER] key once.
8
The display should now be showing "+NOT DETECTING+".
Moving around the menu is explained on page 6 of the Operators Guide.
Step Two
The correct parameters must now be entered into the configuration menu. To gain access to the