Outdoor Unit Installation Instructions
Mounting the Outdoor Unit to the Selected Location
The outdoor unit should be installed either on a pad or on a solid wall and fastened securely.
Follow the procedure below before connecting any pipes or cables:
• Decide what the best position on the wall or on the ground is, and leave enough space to be
able to carry out maintenance easily. Anchoring dimensions are provided on Page 42.
• If wall mounting, fasten the support brackets to the wall using hardware that is particularly
suited for the type of wall. Use the appropriate amount of hardware for the application.
• The unit must be installed following all national regulations.
Outdoor Unit Condensate Water Drainage
The condensate water and the ice formed in the outdoor unit during heat mode can be
directed away using the optional drain line included with the system.
1. Fasten the drain port in the 1-inch port located
in the part of the unit depicted in the diagram.
2. Connect the drain port and the drain line.
3. Ensure the condensate will drain to a suitable place.