Indoor Unit Installation Instructions
Installation of the Mounting Plate
1. Place the included mounting plate against the
wall where the system will hang that fulfills the
constraints on Page 22. Use a level to ensure that
the plate is horizontally level.
2. Drill 1.3" deep holes for each screw to enter, the
locations are flexible but should be spaced well.
3. Insert the plastic anchors into each of the holes.
4. Fix the mounting plate to the wall by using the
included tapping screws. Check that it is secured.
Note: The actual appearance of the mounting plate
may differ slightly but the process is similar.
Drilling the Wall Hole for Piping
CHECK PAGES 42-43 FOR MOUNTING HOLE
GUIDELINES ACCORDING TO THE BRACKET.
1. With the mounting plate firmly affixed to the
wall, mount the indoor unit onto the mounting
plate temporarily in order to determine the
location of the wall hole in the next steps.
2. Using a pencil, lightly trace the bottom corner of
the indoor unit, depending on which side exit
the piping will go through (see Page 26).
3. Take the inside unit off of the plate, and make a
mark of where the hole will be (PG. 42-43), to ensure
ample clearance between the tracing and bracket.
4. Drill a 2.5" wall hole at a slight downward
angle using a core drill, being careful to avoid
wires, plumbing, and other sensitive materials.
The bottom of the inside hole should be ~1/4"
above the bottom of the outside hole.
Page 24
1
If doing right side exit...
2
3
Indoors
6
ø 2.5"
Outdoors
"
0.2
(5mm)