Indoor Unit Installation Instructions
Connecting the Drain Hose
By default, the drain hose is attached to the left-hand side of
unit ("left" when facing the back of the unit). However, it can
also be attached to the right-hand side.
1. To ensure proper drainage, attach the drain hose on the
same side that your refrigerant piping exits the unit.
2. Attach any drain hose extensions (sold separately) to the
end of drain hose.
3. Wrap the connection point firmly with Teflon tape to
create a good seal, and to prevent leaks.
4. For the portion of the drain hose that will remain indoors,
wrap it with foam pipe insulation to prevent condensation.
5. Remove the air filter and pour a small amount of water into
the drain pan to make sure that water flows from the unit
smoothly.
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose according
to
the illustrations.
kink the drain hose.
DO NOT
create a water trap (siphon).
DO NOT
put the end of the drain hose in
DO NOT
water or in a container that will collect water.
DUAL DRAIN HOLE LOCATIONS EXIST
The indoor unit has 2 drain connections on left and
right sides. Either one can be utilized. One side will
have a hose connected, while the other is plugged.
6
YES
NO
NO