fan synch. operation
Select whether the fan is to maintain the same speed,
regardless of whether the compressor is operating or
not, or alternatively run at different speeds. If the func-
tion is activated, fan speed 2 applies when the com-
pressor is not in operation, and normal fan speed applies
when the compressor is in operation.
MENU 5.2 - SYSTEM SETTINGS
Make different system settings for the heat pump here,
e.g. which accessories are installed.
MENU 5.2.4 - ACCESSORIES
Inform the heat pump which accessories are installed
here.
There are two ways of activating connected accessories.
You can either mark the alternative in the list or use the
automatic function "search installed acc.".
search installed acc.
Mark "search installed acc." and press the OK button to
automatically find connected accessories for F370.
MENU 5.3 - ACCESSORY SETTINGS
The operating settings for accessories that are installed
and activated are made in the sub-menus for this.
MENU 5.3.3 - EXTRA CLIMATE SYSTEM
mixing valve amplifier
Setting range: 0.1 – 10.0
Default value: 1.0
mixing valve step delay
Setting range: 10 – 300 s
Default values: 30 s
Contr. pump GP10
Setting range: on/off
Factory setting: off
Here, you select which climate system (2 - 8) you wish
to set.
mixing valve amplifier, mixing valve step delay: Here,
you set the shunt amplification and shunt waiting time
for the various extra climate systems that are installed.
Contr. pump GP10: Here, you can set the speed of the
circulation pump manually.
See the accessory installation instructions for function
description.
50
Chapter 8 | Control - Menus
MENU 5.3.21 - FLOW SENSOR / ENERGY
METER
Energy meter
set mode
Setting range: energy per pulse / pulses per kWh
Default value: energy per pulse
energy per pulse
Setting range: 0 – 10000 Wh
Factory setting: 1000 Wh
pulses per kWh
Setting range: 1 – 10000
Factory setting: 500
Energy meter (Electricity meter)
The energy meter(s) is used to send pulse signals every
time a certain amount of energy has been consumed.
energy per pulse: Here you set the amount of energy
to which each pulse will correspond.
pulses per kWh: Here you set the number of pulses per
kWh that are sent to F370.
MENU 5.4 - SOFT IN/OUTPUTS
Here you can select the input/output on the input board
(AA3) to which the external switch function
is to be connected.
Selectable inputs on terminal block AUX 1-5 (AA3-X6:9-
18) and output AA3-X7 on the input board.
MENU 5.5 - FACTORY SETTING SERVICE
All settings can be reset (including settings available to
the user) to default values here.
Caution
When resetting, the start guide is displayed
the next time the heat pump is restarted.
MENU 5.6 - FORCED CONTROL
You can force control the different components in the
heat pump and any connected accessories here.
MENU 5.7 - START GUIDE
When the heat pump is started for the first time the
start guide starts automatically. Start it manually here.
See
page 34
for more information about the start guide.
MENU 5.8 - QUICK START
It is possible to start the compressor from here.
(page
29)