SETTING THE VENTILATION
The ventilation must be set according to applicable
standards. The fan speed is set in menu 5.1.5 .
Even if ventilation is roughly set at installation it is im-
portant that a ventilation adjustment is ordered and
permitted.
NOTE
Order a ventilation adjustment to complete the
setting.
Ventilation capacity
Available pressure
Tryck
(Pa)
700
600
500
400
300
200
100
40%
30%
0
0
20
40
Fan rating
Effekt
Output
(w)
160
140
120
100
80
60
40
20
40%
30%
0
0
20
40
NIBE F370
100%
90%
80%
70%
60%
50%
60
80
100
120
Airflow
Flöde
(l/s)
100%
90%
80%
70%
60%
50%
60
80
100
120
Airflow
Luftflöde
(l/s)
COMMISSIONING WITHOUT FAN
The heat pump can be run without recovery, as only an
electric boiler, to produce heat and hot water, for ex-
ample before the ventilation installation is complete.
Enter menu 4.2 - "op. mode" and select "add. heat only"
Enter menu 5.1.5 - "fan sp. exhaust air" and reduce the
fan speed to 0%.
NOTE
Select operating mode "auto" or "manual" when
the heat pump is to run on recovery again.
Chapter 6 | Commissioning and adjusting