PENSOTTI Solenne PCH50B-H Instruction Manual page 65

Condensing direct vent gas boiler 170,000 btu input
Hide thumbs Also See for Solenne PCH50B-H:
Table of Contents

Advertisement

Safety thermostat (see fig. 1)
Disconnect the connecting wire;
Unscrew the fixing screws and remove the
thermostat;
Replace the thermostat and re-assemble
the components following the above
procedure in reverse order;
Switch on the electricity, water and gas
supplies and restart the appliance.
Heating sensor (see fig. 1)
Un-Plug the connecting wire;
Replace the sensor and re-assemble the
components
following
procedure in reverse order;
Switch on the electricity, water and gas
supplies, open the shut-off valves and fill
the central heating circuit. Then restart the
appliance, remembering to discharge any air that may be trapped in the system;
Gas valve (see fig. 2)
Unscrew the screws connecting the gas
valve to the venturi.
Disconnect the gas feed pipe and valve ring-
nut at the bottom of the room-sealed chamber.
Remove the flanged elbow coupling of the
existing valve and fit it to the new valve; also
fit a new cork washer and a new fiber gasket.
Replace the gas valve and re-assemble the
components following the above procedure in
reverse order.
Replace all the gas seals.
Fully tighten the gas connections.
Switch on the electricity, water and gas
supplies and check for any gas leaks using a
soapy solution or leak detector spray;
MAINTENANCE INSTRUCTIONS
heating sensor
the
above
safety thermostat
Fig. 1
Fig. 2
gas valve
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pci 18/8-h

Table of Contents