Securing The Q-Drive System; Attaching Power Connections; Attaching The Process Gas Filter - Haskel Q-Drive QGD Series Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Securing the Q-Drive System

The drive requires 4 anchor bolts. The mounting holes are 21.8 mm (0.866 in) in diameter.
1. Insert the 4 anchor bolts. Do not lubricate.
2. Level the system.
Leveling Bolts

Attaching Power Connections

Use a Mennekes® 3 Phase twist-lock connector.

Attaching the Process Gas Filter

The owner is responsible for filtration of any inlet process media to the QDRIVE system.
The filter should not have more than 1% pressure drop across it @ the flowrate (in order not
to lose incoming media pressure).
The filter should be rated for the incoming media pressure and temperature.
Q-Drive Installation, Operation, and Maintenance Manual
Bottom View of Q-Drive with Location of Anchor Bolts
Mennekes® 3 Phase twist-lock connector
13 of 59
Clearance Holes
for Anchor Bolts

Advertisement

Table of Contents
loading

Table of Contents