Performance; Specifications - Haskel Q-Drive QGD Series Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Performance

Minimum
Model
Inlet
psi (bar)
QGT150-90
75 (5)
QGT150-63
75 (5)
QGT90-63
75 (5)
QGD150
75 (5)
QGD90
75 (5)
QGD63
75 (5)
1 Consult Haskel representative for higher speed and pressure requirements.

Specifications

Physical Environment
Dimensions
Weight
Noise Level
Connections (Haskel International recommends BuTech ¾ in M/P fittings and tubing.)
Blow By
Purge
Vent Lines
Gas Outlet and Inlet
Air Supply
Coolant Outlet and Inlet
Coolant System
Maximum Pressure
Coolant Ratio
Coolant Flow
Electrical System
Heating Power
Supply Current
Frequency
Lubrication System
Oil type
Capacity
Gas Temperature
Maximum Temperature
Minimum Temperature at Inlet
Operating Environment
Q-Drive Installation, Operation, and Maintenance Manual
Maximum
Maximum
Inlet
Outlet
psi (bar)
psi (bar)
440 (30)
3400 (234)
220 (15)
6600 (455)
1500 (104)
6600 (455)
1150 (80)
1150 (80)
3400 (235)
3400 (235)
6600 (455)
6600 (455)
98 in L x 34 in W x 54 in H
2.5 m L x 0.86 m W x 1.4 m H
2500 lbs (estimated max)
1134 kgs
77.0 dB(A)
3/4 in tube OD, 316 SST
1/4 in tube OD, 316 SST
3/8 in tube OD, 316 SST
1/2 in tube OD, 316 SST
1/2 in NPT female, brass for 80-120 psi
0.04 SCF at 100 psi (shop air)
1/2 in BSPP female
150 psig (10.3 barg)
80% glycol: 20% water by volume
14 usg/min (3.18 m3/hr)
3-Phase 380-480 V
60 A
50-60 Hz
Syn-Gear EP150
30 litres (8 gallons)
370 °F (188 °C)
32 °F (0 °C)
11 of 59
Maximum
Recommended
Minimum
Compression
Speed
Ratio (Cr)
(CPM)
25
1
25
1
25
1
5
1
5
1
5
1
Maximum
Stroke Force
Maximum
(kN) / lbf
Speed
1
(CPM)
40
150 / 33,721
40
150 / 33,721
40
150 / 33,721
40
150 / 33,721
40
150 / 33,721
40
150 / 33,721