  • Page 1 NC-1 Series Crane Scale OWNER’S MANUAL...
  • Page 2: Table Of Contents

    CONTENTS PRECAUTIONS INSTRUCTION FEATURES & MAIN FUNCTIONS TECHNICAL SPECIFICATION DESCRITION OF OVERALL THE OPERATIONS TEST MODE SET MODE BATTERY OPERATION REMOTE CONTROL ASSEMBLE AND DISASSEMBLY ERROR MESSAGE & TROUBLE SHOOTING...
  • Page 3: Precautions

    This will minimize maintain periodical check by your Internal mechanism could be damaged. defect occurs, contact defect or electric shock. CAS authorized dealer. batteries is hazardous. your CAS authorized dealer immediately for proper repair. Do not pull the plug by its cord when...
  • Page 4: Instruction

    INSTRUCTION TECHNICAL SPECIFICATION We greatly appreciate your purchase of the NC-I. Max Capacity 20kg 30kg 50kg 100kg 200kg 500kg These goods perform excellently and exhibit splendid properties through strike tests. Kilogram Before using the NC-I, it is recommended that you read this manual carefully so you Division 100g 200g...
  • Page 5: Descrition Of Overall

    3.LAMP of DISPLAY PART(Front body) DESCRIPTION OF OVERALL Power Being connected the Adapter 1. OVERALL VIEW Charge RED In charge GREEN Charge is completed FRONT VIEW REAR VIEW Remocon Receiving part from remote controller Display the battery recharging time (rechargeable battery)- about 6.7V remain JOINT RING ASSY Below zero...
  • Page 6: The Operations

    Remove tare on the hook. THE OPERATION 1. POWER ON Press "ON/OFF" key. 2. ZERO OPERATION Press "ZERO" key when the zero point is drifted. Press "TARE" key. The tare weight is cleared appers in the display window. 3. TARE OPERATION Load tare on the hook.
  • Page 7: Test Mode

    4. UNIT CONVERSIONS Test menu ( tESt 1~5) Place an item to be weight on the hook.(GRAM MODE) : Display Test : Load Cell and A/D Conversion Test : The IC(CPU) Temperature Test : Battery Test : Key Test Available keys KEYS FUNCTIONS Remove weight on the hook.
  • Page 8: Set Mode

    TEST 3 SET MODE FUNCTION : The IC (CPU) Temperature TEST How to enter SET Mode DESCRIPTION KEYS LCD SCREEN Turn on the power while pressing key , after displaying the message TARE Display TEST 3 state and then enter the SET Mode. Display the temperature of IC [CPU] Return to the normal mode if you press the key or...
  • Page 9 FUNCTION : Setting the value of Digital-Filter FUNCTIN : Weight Backup DESCRIPTION KEYS LCD SCREEN Setting value DESCRIPTION LCD SCREEN Setting value 00 : Not use Digital-Filter Not use TARE TARE (Speed of display conversion is fast) Use (Zero, Tare, Status) 09 : Speed of display conversion is slow FUNCTION : Setting the stable time of weight (step : 0.1 sec.) FUNCTION : Hold Type...
  • Page 10: Battery Operation

    In Hold state BATTERY OPERATION - if the weight is not changed, the current weight is not changed - if the weight is changed(above the 10% of Max capa), the current weight is changed and 1. CHARGE the Hold function is released A.
  • Page 11: Remote Control

    3. LOW BATTERY("BAT.") SIGNAL Voltage 1.5V A. To protect over-discharge of Battery, A. To protect over-discharge of Battery, AA Size(14.5 X 50.5 m/m) - Battery Size BAT LAMP is on when battery has to be charge. (80% of full charged voltage) Place batteries in correct polarity(+)(-)direction.
  • Page 12: Error Message & Trouble Shooting

    (Charging time is about 4~5 hours) Put the platform on a flat place without shaking and power on If you can see the same massage continuously, call your CAS dealer please. If you can see the same massage continuously, call your CAS dealer please.