KDK E50DZUA Operation Instructions Manual page 37

Energy recovery ventilator
Table of Contents

Advertisement

‫ﺍﻟﺗﺣﻛﻡ ﺑﺎﻟﻬﻭﺍء‬
‫ﺍﻟﻁﺎﻗﺔ ﺍﻟﺧﺎﺻﺔ‬
‫ﻻ ﺗﻭﺟﺩ ﻧﻘﻁﺔ‬
‫ﺑﺎﻟﺗﺣﻛﻡ ﺑﺎﻟﻬﻭﺍء‬
‫ﺍﺗﺻﺎﻝ ﻟﻠﺟﻬﺩ‬
‫022 ﻓﻭﻟﺕ‬
‫06~ ﻫﺭﺗﺯ‬
‫ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ‬
‫ﻓﻲ ﺍﻟﻬﻭﺍء‬
‫ﺍﻟﻣﻔﺗﺎﺡ‬
(‫)ﻳﻌﺩﻩ ﺍﻟﻌﻣﻳﻝ‬
‫ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ‬
‫022 ﻓﻭﻟﺕ‬
‫06~ ﻫﺭﺗﺯ‬
‫ﻣﻔﺗﺎﺡ ﻣﺯﺩﻭﺝ ﺍﻷﻗﻁﺎﺏ‬
(‫)ﻳﻌﺩﻩ ﺍﻟﻌﻣﻳﻝ‬
‫)ﻧﻘﻁﺔ ﺗﻭﺻﻳﻝ ﺑﻣﺳﺎﻓﺔ ﻓﺎﺻﻠﺔ‬
(‫ﺗﺗﻌﺩﻯ 3 ﻣﻡ‬
‫ )ﻟﻸﺳﻼﻙ‬IEC 53 60227 ‫ﻳﻔﺿﻝ ﺍﺳﺗﺧﺩﺍﻡ ﺳﻠﻙ ﻟﺗﻭﺻﻳﻝ ﺍﻟﻁﺎﻗﺔ ﻭﺍﻟﺗﺑﺩﻳﻝ، ﺑﺟﻬﺩ ﻣ ُﻘﻧﻥ ﻣﻘﺩﺍﺭﻩ 003 ﻓﻭﻟﺕ / 005 ﻓﻭﻟﺕ ﻭﻓﻘ ً ﺎ ﻟﻣﻌﺎﻳﻳﺭ‬
1 ‫ﻳﺭﺟﻰ ﺍﺳﺗﺧﺩﺍﻡ ﺳﻠﻙ ﺫﻭ ﺛﻼﺛﺔ ﺃﻁﺭﺍﻑ ﻳﺣﺗﻭﻱ ﻋﻠﻰ ﺳﻠﻙ ﺃﺧﺿﺭ/ﺃﺻﻔﺭ ﻟﻭﺻﻠﺔ ﺍﻟﻁﺎﻗﺔ؛ ﺇﻟﻰ ﺟﺎﻧﺏ ﺍﺳﺗﺧﺩﺍﻡ ﺳﻠﻙ ﺑﻁﺭﻓﻳﻥ ﻟﺗﻭﺻﻳﻝ ﺍﻟﻣﻔﺗﺎﺡ‬
‫ﻭﺍﻟﻣﻔﺗﺎﺡ 2، ﻭﺍﻟﻣﻔﺗﺎﺡ ﺍﻟﻣﻭﺟﻭﺩ ﺩﺍﺧﻝ ﺍﻟﻭﺣﺩﺓ؛ ﺍﺳﺗﺧﺩﻡ ﺍﻟﺳﻠﻙ ﺫﻭ ﺍﻟﻁﺭﻓﻳﻥ ﻟﻠﺗﺣﻛﻡ ﻓﻲ ﺍﻟﻬﻭﺍء )ﻳﺭﺟﻰ ﺣﺫﻑ ﺍﻟﺗﻭﺻﻳﻝ ﺇﺫﺍ ﻛﻧﺕ ﻟﻥ ﺗﺳﺗﺧﺩﻡ‬
‫ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﻟﻬﻭﺍء(، ﻭﺍﺳﺗﺧﺩﻡ ﺍﻟﺳﻠﻙ ﺫﺍ ﺍﻷﻁﺭﺍﻑ ﺍﻷﺭﺑﻌﺔ ﻟﺗﻭﺻﻳﻝ ﺍﻷﻁﺭﺍﻑ ﺍﻷﺧﺭﻯ ﻣﻊ ﺍﻟﻣﻔﺗﺎﺡ، ﺍﻟﻣﻘﻁﻊ ﺍﻟﻌﺭﺿﻲ ﺍﻻﺳﻣﻲ ﻟﻠﺳﻠﻙ ﺍﻟﻣﺫﻛﻭﺭ‬
.2‫ﺃﻋﻼﻩ ﻫﻭ 5.2 ﻣﻡ2. ﻋﻧﺩ ﺍﺳﺗﺧﺩﻡ ﺟﻬﺎﺯ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑ ُﻌﺩ ﻟﻠﻣﻔﺗﺎﺡ، ﻓﺈﻥ ﺍﻟﺳﻠﻙ ﺍﻟﻣﺗﺻﻝ ﺑﺎﻟﻣﻔﺗﺎﺡ، ﻳﺟﺏ ﺃﻥ ﻳﺑﻠﻎ ﻣﻘﻁﻌﻪ ﺍﻟﻌﺭﺿﻲ 5.1 ﻣﻡ‬
.‫ﻳﺭﺟﻰ ﺍﺳﺗﺧﺩﺍﻡ ﻋﺯﻡ ﺩﻭﺭﺍﻥ ﺃﻗﻝ ﻣﻥ 2.1 ﻧﻳﻭﺗﻥ ﻹﺣﻛﺎﻡ ﺭﺑﻁ ﺍﻟﺳﻠﻙ ﺍﻟﺭﺋﻳﺳﻲ ﻭﺃﺟﺯﺍء ﺍﻷﻁﺭﺍﻑ، ﻻ ﺗﺩﻉ ﺃﻱ ﺗﻭﺻﻳﻼﺕ ﺩﻭﻥ ﺭﺑﻁﻬﺎ ﺑﺈﺣﻛﺎﻡ‬
‫ﻳﻣﻛﻥ ﺗﻌﺩﻳﻝ ﻣﻘﺩﺍﺭ ﺍﻟﻬﻭﺍء ﻋﺑﺭ ﻭﺿﻌﻳﻥ ﻣﺭﺗﻔﻊ/ ﻣﻧﺧﻔﺽ ﻭﺷﺩﻳﺩ/ﻣﻧﺧﻔﺽ ﺿﺑﻁ ﺍﻟﻣﺻﻧﻊ ﻳﻛﻭﻥ ﻋﻠﻰ ﻣﺭﺗﻔﻊ +ﻣﻧﺧﻔﺽ. ﻳﺭﺟﻰ ﺗﻌﺩﻳﻠﻪ ﻭﻓﻘ ً ﺎ‬
‫ﻋﻧﺩ ﺿﺑﻁ ﻣﻘﺩﺍﺭ ﺍﻟﻬﻭﺍء ﻣﻥ ﻋﺎﻝ ٍ ﺇﻟﻰ ﺷﺩﻳﺩ، ﻳﺭﺟﻰ ﻋﺯﻝ ﻣﻭﺻﻝ ﺍﻟﺧﻁ ﺍﻷﺣﻣﺭ ﻭﺍﻟﺧﻁ ﺍﻷﺯﺭﻕ، ﻭﺭﺑﻁ ﻣﻭﺻﻝ ﺍﻟﺳﻠﻙ ﺍﻷﺣﻣﺭ ﻭﺍﻟﺳﻠﻙ‬
.‫ﺇﺫﺍ ﻛﺎﻧﺕ ﻫﻧﺎﻙ ﻋﺩﺓ ﻭﺣﺩﺍﺕ ﺗﻌﻣﻝ ﻣ ﻌ ًﺎ، ﻓﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﺇﺟﻣﺎﻟﻲ ﺍﻟﺗﻳﺎﺭ ﻟﺟﻣﻳﻊ ﺍﻟﻣﻌﺩﺍﺕ ﺃﻗﻝ ﻣﻥ ﻧﺻﻑ ﺍﻟﺟﻬﺩ ﺍﻟﻣﻘﻧﻥ ﻟﻠﻣﻔﺗﺎﺡ‬
‫ﻟﺗﺟﻧﺏ ﺍﻟﺧﻁﺭ، ﻋﻧﺩ ﺗﻠﻑ ﻭﺻﻠﺔ ﺍﻟﻁﺎﻗﺔ، ﻳﺭﺟﻰ ﺍﻻﺳﺗﻌﺎﻧﺔ ﺑﻔﻧﻲ ﻣﻌﺗﻣﺩ ﻟﻠﻘﻳﺎﻡ ﺑﻌﻣﻠﻳﺔ ﺍﻻﺳﺗﺑﺩﺍﻝ، ﻭﺫﻟﻙ ﻣﻥ ﺧﻼﻝ ﺍﻻﺗﺻﺎﻝ ﺑﻣﺗﺟﺭ ﺍﻟﺷﺭﺍء ﺃﻭ‬
‫ﺑﺭﺗﻘﺎﻟﻲ‬
‫ﺑﻧﻲ‬
‫ﺑﻧﻲ‬
A2
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
A1
‫ﺃﺯﺭﻕ‬
Damper
‫ﺃﺣﻣﺭ‬
‫ﺃﺯﺭﻕ‬
HI
‫ﺭﻣﺎﺩﻱ‬
‫ﺃﺑﻳﺽ‬
LO
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
COM
‫ﺑﺭﺗﻘﺎﻟﻲ‬
‫ﺃﺑﻳﺽ‬
SW2
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
‫ﺭﻣﺎﺩﻱ‬
SW1
‫ﺃﺣﻣﺭ‬
‫ﺃﺑﻳﺽ‬
N
‫ﺃﺳﻭﺩ‬
L
‫ﻣﺟﻣﻭﻋﺔ ﺍﻷﻁﺭﺍﻑ‬
‫ﺍﻟﻭﺣﺩﺓ ﺍﻟﺭﺋﻳﺳﻳﺔ ﺍﻟﺛﺎﻧﻳﺔ‬
‫ﻣﺟﻣﻭﻋﺔ ﺍﻷﻁﺭﺍﻑ‬
SW1 SW2
L
N
‫ﺍﻟﻭﺣﺩﺓ ﺍﻟﺭﺋﻳﺳﻳﺔ ﺍﻟﺛﺎﻟﺛﺔ‬
.‫ﻳﺟﺏ ﺗﻭﺻﻳﻝ ﺍﻟﺧﻁ ﺍﻟﻣﺗﻘﻁﻊ ﻛﻣﺎ ﻫﻭ ﻣﺑﻳﻥ ﻓﻲ ﺍﻟﺷﻛﻝ ﻋﻠﻰ ﺍﻟﻔﻭﺭ ﻣﻥ ﻗﺑﻝ ﻋﻣﺎﻝ ﺍﻟﺑﻧﺎء‬
.‫ﻳﺭﺟﻰ ﺍﺳﺗﺧﺩﺍﻡ ﻣﻔﺗﺎﺡ، ﺑﻧﻘﻁﺔ ﺍﺗﺻﺎﻝ ﺫﺍﺕ ﻣﺳﺎﻓﺔ ﻋﺎﺯﻟﺔ ﺗﺗﻌﺩﻯ 3 ﻣﻡ‬
.‫ﻳﺭﺟﻰ ﻣﻼﺣﻅﺔ ﻋﺩﻡ ﺗﻭﺻﻳﻝ ﺃﻭ ﺗﺛﺑﻳﺕ ﻭﺻﻠﺔ ﺍﻟﻁﺎﻗﺔ ﺑﺎﺳﺗﺧﺩﺍﻡ ﺍﻟﻠﺣﺎﻡ‬
.‫ﺑﻌﺩ ﺍﻻﻧﺗﻬﺎء ﻣﻥ ﺗﻭﺻﻳﻝ ﺍﻷﺳﻼﻙ، ﻳﺭﺟﻰ ﺗﺛﺑﻳﺕ ﻏﻁﺎء ﺻﻧﺩﻭﻕ ﺍﻟﻣﻔﺗﺎﺡ ﺑﺎﺳﺗﺧﺩﺍﻡ ﺍﻟﻣﺳﺎﻣﻳﺭ‬
(‫ﺗﻭﺻﻳﻝ ﺍﻟﻁﺎﻗﺔ )ﻗﺑﻝ ﺑﻧﺎء ﺍﻟﺳﻘﻑ‬
‫ﻣﺧﻁﻁ ﺗﻭﺻﻳﻝ ﺍﻷﺳﻼﻙ‬
7
4
8
6
2
‫ﺃﺳﻭﺩ‬
3
5
1
1 ‫ﺍﻟ ﻣ ُﺭﺣﻝ‬
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
4
4
7
4
‫ﺃﺳﻭﺩ‬
‫ﺃﺳﻭﺩ‬
3
3
8
6
2
‫ﺃﺻﻔﺭ‬
‫ﺃﺻﻔﺭ‬
2
2
3
‫ﺃﺑﻳﺽ‬
1
‫ﺃﺑﻳﺽ‬
1
5
1
2 ‫ﺍﻟ ﻣ ُﺭﺣﻝ‬
‫ﻣﻭﺻﻝ‬
‫ﻣﻭﺻﻝ‬
‫ﻣﻛﺛﻑ‬
‫ﺑﺭﺗﻘﺎﻟﻲ‬
7
‫ﺃﺣﻣﺭ‬
4
8
‫ﺃﺻﻔﺭ‬
(
LO
)
‫ﺃﺻﻔﺭ‬
6
2
3
‫ﺃﺣﻣﺭ‬
(
)
‫ﺃﺯﺭﻕ‬
HI
5
1
(
)
SH
‫ﺃﺑﻳﺽ‬
1 ‫ﺍﻟ ﻣ ُﺭﺣﻝ‬
‫ﻣﻭﺻﻝ‬
‫ﻣﻭﺻﻝ‬
Damper
COM
LO
HI
A1 A2
..‫ﻳﺭﺟﻰ ﺍﺳﺗﺧﺩﺍﻡ ﻣﻔﺗﺎﺡ، ﺑﺷﺩﺓ ﺗﻳﺎﺭ ﻣﻘﻧﻧﺔ ﺗﺑﻠﻎ 01 ﺃﻣﺑﻳﺭ‬
..‫ﻟﻁﻠﺏ ﺍﻟﻌﻣﻳﻝ ﺇﺫﺍ ﻟﺯﻡ ﺍﻷﻣﺭ‬
.(‫ﺍﻷﺑﻳﺽ )ﻛﻣﺎ ﻫﻭ ﻣﻭﺿﺢ ﻋﺑﺭ ﺍﻟﺧﻁ ﺍﻟﻣﻧﻘﻁ‬
2
‫ﻣﺧﻁﻁ ﺗﻭﺻﻳﻝ ﺍﻷﺳﻼﻙ‬
‫ﺍﻟﻭﺣﺩﺓ ﺍﻟﺭﺋﻳﺳﻳﺔ‬
‫ﻣﻭﺗﻭﺭ‬
‫ﺍﻟﺗﺭﻁﻳﺏ‬
‫ﺃﺯﺭﻕ‬
‫ﺃﺳﻭﺩ‬
‫ﺃﺻﻔﺭ‬
‫ﺃﺑﻳﺽ‬
‫ﻣﻔﺗﺎﺡ ﺍﻟﻘﺻﺭ‬
6
‫ﺃﺳﻭﺩ‬
‫ﺑﺭﺗﻘﺎﻟﻲ‬
5
‫ﺃﺣﻣﺭ‬
4
‫ﺍﻟﻣﻭﺗﻭﺭ‬
‫ﺃﺻﻔﺭ‬
3
‫ﺃﺯﺭﻕ‬
2
1
‫ﺃﺑﻳﺽ‬
:‫ﺍﺣﺗﻳﺎﻁﺎﺕ ﺗﻭﺻﻳﻝ ﺍﻷﺳﻼﻙ‬
.(‫ﺍﻟﺭﻓﻳﻌﺔ‬
.‫ﻳﻠﺯﻡ ﻭﺟﻭﺩ ﻭﺻﻠﺔ ﺃﺭﺿﻲ‬
.‫ﻣﺭﻛﺯ ﺍﻹﺻﻼﺡ‬
37