Please don't set the indoor air inlet in locations
with high temperature or high humidity.
It may cause the damage inside the unit,
which can result in abnormal operation,
Prohibition
electric shock and fi re.
Please install it on the ceiling that is strong
enough to hold the unit, otherwise the ceiling
should be reinforced.
Besides, please install the unit by the
specifi ed methods.
Please don't install it in the high humidity place
such as bathroom.
It may cause the electric shock and
abnormal operation.
Prohibited to
use in location
with water
Please install inside the insulated space (the
space is insulated from outdoor air).
If installing it outside the insulated space
(the space exposed to the outdoor air), the
internal unit will be dewed in winter, it may
cause the electric shock or water dropping.
Please install the outdoor air duct in a inclined way
Improper installation will cause the water
seepage in the room and wet the goods.
Please install the main unit in locations where
dust and dirt can't come in.
Large amount of dirt and dust clogged in
fi lter will cause the lack of oxygen in rooms.
Don't install the main unit and indoor air inlet
in locations with excessive cooking smoke
such as kitchen.
It may cause the fi re.
Prohibition
Specifi ed part must be used during the
installation (include the accessories).
It may cause the unit dropping, fi re and
electric shock If not using the specifi ed
parts.
The appliance is forbidden to operate without
Filter Box Unit.
Otherwise dirt or dust will accumulate in
the energy recovery core. It will lower its
performance and dirt or dust will go into
room.
CAUTION
Dropping may
cause the injury.
Contact
prohibition
Prohibition
Please install the anti-bird nest or similar
accessory in air duct.
Please remove the abnormality such as
bird nets, otherwise it may cause the
lack of oxygen in rooms.
Please connect according to the electrical
equipment technology benchmark and indoor
lead wire regulation.
Wrong wire connection will cause the
electric leakage, electric shock and fi re.
Please don't insert the fi ngers and stick into
the rotation part during the operation.
It may cause the injury.
Owing to different installation positions for
special purpose circuit breaker, sometimes it's
required to install the anti-creeping circuit
breaker.
It may cause the electric leakage if not
installing the anti-creeping circuit
breaker.
The air duct which connects the outdoor to
indoor should be prevented to occur the dew.
Improper installation will cause the water
leakage in room, result in damaging the
indoor property.
Firmly fi x the parts.
Dropping may cause the injury.
Don't install the main unit and indoor air inlet
in location with high temperature or directly
exposed to heat source.
It may heat or cause the fi re.
Please install the pipe hood for preventing
strong wind from outside (separately buy).
Please stop the unit during the strong
wind and sandstorm as they may enter
the room along the air duct.
Circular pipe hood
MCX100K
For project: With fl y
nest & without fl y nest
11