TERMINAL DESIGNATION
Terminal functions
Symbol
Terminal name
Main
L1/L, L2/N
Power input
circuit
U, V, W
Inverter output
P1, P(+)
For DC REACTOR
G
Earth
Analog
13
Potentiometer
input
12
Voltage input
(PID control)
C1
Current input
(PID control)
11
Common
Digital
FWD
Forward operation
i nput
command
REV
Reverse operation
command
X1
Digital input 1
X2
Digital input 2
X3
Digital input 3
(SS1)
Multistep freq.
(SS2)
select
(BX)
Coast-to-stop
command
(RST)
Alarm reset
(THR)
Trip command
(External fault)
(WE-KP)
Write enable for
KEYPAD
(Hz/PID)
PID control cancel
(LE)
Link enable
(RS485: Option)
P24/CM
P24: DC voltage supply
11
CM: common
Analog
FM
Analog monitor
output
11
(Common)
Relay
30A, 30B
Alarm relay
output
30C
output
Terminal arrangement
G Main circuit terminals
1-phase
Input
G
L1/L
L2/N
Output
3-phase
P(+)
N(-)
U
V
7
Connect 1-phase 200V power supply
Connect 3-phase induction motor
Connect the DC REACTOR (option) for power-factor
correction or harmonic current reduction
Terminal for inverter chassis
+10VDC power supply for setting potentiometer (POT: 1 to 5kΩ)
0 to +10VDC/0to 100% (0 to +VDC/0 to 100%)
Used for PID control reference signal or feedback signal
4 to 20mA DC/0 to 100%
Used for PID control feedback signal or reference signal
Common for analog signals
FWD – ON ........ The motor runs in the forward direction
FWD – OFF ...... The motor decelerates and stops
REV – ON ........ The motor runs in the reverse direction
REV – OFF ...... The motor decelerates and stops
These terminals can be preset as follows
(SS1):
0, 1 different frequencies can be selectable
(SS1, SS2): 0 to 3 different frequencies can be selectable
(BX) – ON ...... Motor will coast-to-stop
(No alarm signal will be output)
(RST) – ON ...... Faults are reset
(This signal should be held for more than 0.1s)
(THR) – OFF ...... "0H2 trip" occur and motor will coast-to-stop
(WE-KP) – ON ...... The data will be changed by KEYPAD panel
(Hz/PID) – ON ...... The PID control is cancelled and KEYPAD panel frequency
setting (
or
(LE) – ON ...... The link operation is effective
DC voltage supply (+24V, max 100mA)
Common for digital signal
• Output voltage (0 to 10VDC) is proportional to selected function's value as follows
. Output frequency (0 to max. frequency)
. Output current (0 to 200%)
. PID feedback value (0 to 100%)
. DC link circuit voltage
• Bias value can be preset
Outputs a contract signal when protective function is activated
Changeable exciting mode active or non-exciting mode active by function No. F36
P1
P(+)
W
G
Function
) is effective
G Control circuit terminals
30A
30B
30C
Remarks
Allowable maximum output currrent: 10mA
• Input impedance: 22kΩ
• Allowable maximum input voltage: 50mA
• If input voltage is 10 to 15VDC, then the inverter
clamps it at 10VDC
• Input impedance: 250Ω
• Allowable maximum input current: 30mA DC
• If input voltage is 20 to 30mA DC, then the
inverter clamps it at 20mA DC
Same potential as CM – 0V
When FWD and REV are simultaneously ON, the
motor decelerates and stops
When FWD and REV are simultaneously ON, the
motor decelerates and stops
• Sink type terminal specifications
• ON state maximum input voltage: 2V
(maximum source current: 6mA)
• OFF state maximum terminal voltage: 24 to 27V
(allowable maximum leakage current: 0.5mA)
0 frequency (All (SS1) and (SS2) signals are OFF)
is set by "F01"
• The motor restarts from 0Hz by turning off BX
with the operation command (FWD or REV) ON
• Assigned to terminal X2 at factory setting
• During normal operating, this signal is ignored
• Assigned to terminal X3 at factory setting
This alarm signal is held internally
For switch link operation to communication
DIPSW select: SW7
Same potential as 11
Allowable maximum output currrent: 2mA
Contact rating:
• 250V AC, 0.3A, cos ø=0.3
• 48VDC, 0.5A, non-inductive
Applicable maximum voltage for CE marking
(Low Voltage Directive)
Applicable maximum voltage for UL/cUL
FM
X1
X2
X3
FWD REV P24/CM
Func. code
F01
F01, H21
F01
F01, H21
F02
E01 to
E03
C05 to
C07
F00
H20 to
H25
F30,
F31
F36
11
12
13
C1

Advertisement