IMO JAGUAR CUB CM Series Manual page 7

Single phase micro-verter 0.2 - 2.2kw

Advertisement

COMMON SPECIFICATIONS
Item
Maximum frequency
Output
frequency
Base frequency
Starting frequency
Carrier frequency
Accuracy (Stability)
Setting resolution
Control
Control method
Voltage/freq. (V/f) characteristic
Torque boost
Starting torque
Operation method
Frequency setting
Running status signal
Acceleration time
Deceleration time
Frequency limiter
Bias frequency
Gain for frequency setting
Jump frequency control
Auto-restart after
momentar y power failure
PID control
Indication
Operation mode
(running or stopping
Program mode
Trip mode
Operation and Trip mode
Charge lamp (Red)
Protection
Overload
Over voltage detection
Under voltage
Overheating
Short-circuit
Ground fault
Motor overload
(running or stopping
Stall prevention
Auto reset
Condition
Installation location
(Installation
Altitude
and
Ambient temperature
operation)
Ambient humidity
Vibration
Storage conditions
50 to 120Hz (in 1Hz steps)
50 to 120Hz (in 1Hz steps)
1 to 6Hz (in 1Hz steps)
0.75 to 15kHz
• Analog setting
: ±1.0% of maximum frequency (at 25 ±10˚C)
• Digital setting
: ±0.01% of maximum frequency (at -10 to +50˚C)
• Analog setting
: 1/256 of maximum frequency ex.) 0.25Hz at 60Hz, 0.5Hz at 120Hz
• Digital setting
: 0.01Hz at maximum frequency of up to 99.9Hz (1Hz at maximum frequency of 100Hz and above)
• Sinusoidal PWM control
Maximum output voltage proportional to line input voltage (without AVR control)
Manual:
Code selection (0 to 31), including the save energy pattern for variable torque load
150% (at 6Hz) (Torque boost code (F09) is 20 and above.)
• KEYPAD operation :
key,
• Digital input signal operation : FWD or REV command
• LINK operation
: RS485 (Option)
• KEYPAD operation :
or
key
• Built-in potentiometer:
Potentiometer is standard equipment
• Analog input:
0 to +10VDC (0 to +5VDC)
v to 20mADC
• Multistep frequency:
4 different frequencies can be selected by terminal (SS1) and (SS2).
• LINK operation:
RS485 (Option)
Relay output:
Alarm output for any fault. (1SPDT)
Analog output:
Output frequency, output current, PID feedback value, DC link circuit voltage
0.0 to 60s (0.0 = 0.01s)
0.1 to 60s
High and low limiter can be preset.
Bias frequency can be preset (-120 to 120Hz)
100% (For 0 to +10VDC) or 200% (For 0 to +5VDC)
Jump frequency (3 points) and its common jump hysteresis width (0 to 30Hz0 can be preset
Automatic restart is available after a momentary power failure (retry method)
This function can control flow rate pressure, etc. (with an analog feedback signal.)
• Reference signal (F01):
• KEYPAD operation (
• Voltage input (Terminal 12)
• Current input (Terminal C1)
• Analog input (Built-in Potentiometer)
• Feedback signal (H21)
• Terminal 12 (0 to +10V DC or 1 to 5V DC)
• Terminal C1 (4 to 20mA DC)
• Output frequency, output current, PID reference value, PID feedback value
• Setting frequency
Function code, data code
Displays trip fault code as follows
• OC1 (Overcurrent during acceleration)
• OC2 (Overcurrent during deceleration)
• OC3 (Overcurrent running at constant speed)
• OU1 (Overvoltage during acceleration)
• OU2 (Overvoltage during deceleration)
• OU3 (Overcurrent running at constant speed)
• LU (Low voltage)
• OH1 (Overheating at heatsink)
• OH2 (External thermal relay tripped)
• OL (Motor overload)
• OLU (Inverter unit overload)
• Er1 (Memory error)
• Er3 (CPU error)
• Er8 (RS485 error)
Trip history (passed/4 times
When the DC link circuit voltage is higher than 50V,. the charge lamp is ON
Protects the inverter by electronic thermal overload relay and detection of inverter temperature
Detects DC link circuit voltage (400V), and stops the inverter
Detects DC link circuit undervoltage (200V) and stops the inverter
Protects the inverter by detection of inverter temperature
Short-circuit protection for inverter output circuit
Ground fault protection for inverter output circuit (detection at starting)
• Protects the motor after the inverter trips
• Electronic thermal overload relay can be selected for standard motor or IMO inverter motor
• Controls the output frequency to prevent
(overcurrent) trip when the output current exceeds the limit value during acceleration
• Lowers the output frequency to hold almost constant torque when the output current exceeds the limit value during operation at constant speed
• Controls the output frequency to prevent
(overvoltage) trip when the DC link circuit voltage exceeds the limit value during deceleration
When the inverter is tripped, it resets automatically and restart. 5-times auto reset can be selected
Free from a dusty location, corrosive gases, oil mist and direct sunlight. Indoor use only
1000m or less. (Applicable to 3000m with power derating: -10%/1000m)
-10˚ to +50˚C
5 to 95% RH (non-condensing)
3mm at 2 to 9Hz, 1m/s
2
at 9 to 200Hz
• Temperature: -25˚ to +65˚C
• Humidity: 5 to 95% RH
JAGUAR CUB CM