Digital Inputs; Digital Outputs; Timer (Interruptible), 16-Bit - Addi-Data APCI-3003 Technical Description

Analog input board, optically isolated
Hide thumbs Also See for APCI-3003:
Table of Contents

Advertisement

Technical data
4.4.2

Digital inputs

Number: .................................................... 4
Input current at 24 V: ............................... 10.5 mA typ.
Input voltage range: .................................. 0-30 V
Optical isolation from the PC: ................... 1000 V DC (one second tested)
Logic "0" level: ......................................... 0-14 V
Logic "1" level: ......................................... 19-30 V
Frequency: ................................................. 1 MHz
4.4.3

Digital outputs

Number: .................................................... 4
Type: ......................................................... Open Collector (OC)
Max. switch current: ................................. 50 mA typ.
Voltage range: ........................................... 5-30 V
Optical isolation from the PC: ................... 1000 V DC (one second tested)
Switching time (load 50 mA):
Switch on: .................................................. 2 µs
Switch off: ................................................. 36 µs
4.4.4

Timer (interruptible), 16-bit

Number: ..................................................... 1
Time base: ................................................. us, ms, s
14
APCI-3003

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APCI-3003 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Addialog apci-3003

Table of Contents