UnsortedChannels = 0 if true, 1 if false. False only used for debugging.
WaveformOversampleCount = fixed by acquisition hardware
Windows = 99 if static, 20 if dynamic
Measurement types
Code
Measurement type
Static Anomaly
SAM
Measurement
Dynamic Anomaly
DAM
Measurements
Background
SBG
Measurement
Background
SBR
Reconnaissance
Measurement
Quality Control (static
SQC
DQC
Dynamic QC (IVS line)
SFT
Function Test
SXM
Miscellaneous
DXM
Miscellaneous
TRANSIENTS
Transients (8288, 2)
Group size = 4
Number of attributes = 1
TransientList = GateTime,ZA,ZB,ZC,ZD,YA,YB,YC,YD,XA,XB,XC,XD (identifies each column as
receiver data with format <direction><Rx cube>, in millivolts)
Static measurements over an identified location with
Dynamic survey for detection and classification of
Static measurement over a non-anomalous location
Static measurement made to confirm SBG location is
Static survey of emplaced IVS targets for QC purposes
IVS)
A direct test of all sensor component responses to a
standard object placed at a precisely know location
Description
an unknown anomaly source
potential MEC
valid
Dynamic survey of an IVS used for QC purposes
(relative to the sensor).
Static all other
Dynamic all other