Torque Sequence

Torque Sequence
1040
Pump Model Numbers D7S___,
D8S___, DRS___ and DSS___
Always follow torque sequence when instructed to
torque fasteners.
1. Left/Right Fluid Covers
Torque bolts to 120-150 in-lb (14-17 N•m)
2. Inlet Manifold
Torque bolts to 120-150 in-lb (14-17 N•m)
3. Outlet Manifold
Torque bolts to 120-150 in-lb (14-17 N•m)
24
1590
Pump Model Numbers DBS___,
DCS___, DTS___, and DUS___
Always follow torque sequence when instructed to
torque fasteners.
1. Left/Right Fluid Covers
Torque bolts to 190-220 in-lb (22-25 N•m)
2. Inlet Manifold
Torque bolts to 120-150 in-lb (14-17 N•m)
3. Outlet Manifold
Torque bolts to 120-150 in-lb (14-17 N•m)