To perform the initial checkout, it is necessary to view the red Fault LED and the four
green status indicators: Power, Input 1, Input 2 and Output. Proceed with caution
around open wiring.
1) Verify that the two actuating devices are properly connected to the DUO-TOUCH
SG Safety Module.
2) Apply power to the Safety Module and to the STB Touch Buttons.
3) Verify that only the Power indicator is ON. If any of the other Safety Module
indicators are ON, dis con nect the power to the safety module and check all wiring.
Do not continue this checkout procedure until the cause of the problem is cor rect ed.
4) Activate both hand controls simultaneously (within 0,5 seconds), and hold them
engaged. Input 1 and Input 2 in di ca tors should come ON. Release both hand
controls simultaneously. K1 and K2 in di ca tors should go OFF, together.
To perform the initial checkout, it is necessary to view the red Fault LED and the four
green status indicators: Power, Input 1, Input 2 and Output. Proceed with caution
around open wiring.
5) Again, activate the two hand controls simultaneously, and hold them engaged.
Input 1 and Input 2 indicators should come ON. Release one hand control, while
holding the other engaged. One of the indicators should remain ON. The Output
indicator should go OFF. Re-activate the hand con trol which was just released.
The Output indicator should remain OFF. Release both hand controls. Input 1 and
Input 2 indicators should then be OFF.
6) Activate only one hand control and hold it engaged. Input 1(Input 2) in di ca tor
should come ON. After more than 1/2 second, activate the second hand control.
Input 1 (Input 2) indicator should remain ON, while Input 2 (Input 1) indicator
remains OFF.
7) Remove power from the Safety Module and disconnect the monitor contact
feed back loop at terminals Y1 and/or Y2. Re-apply power to the Safety Module.
Activate both hand controls si mul ta neous ly. Input 1 and Input 2 indicator LEDs
should remain OFF.
If the DUO-TOUCH SG Safety Module passes all of these tests, reconnect the
output wires at terminals 13/14 and 23/24 and the monitor contact feedback loop at
terminals Y1 and Y2. Do not attempt to use the DUO-TOUCH SG Two-Hand-Control
Safety Module until all of the tests are passed.
10
page
®
DUO-TOUCH

Initial Checkout Procedure

SG –
Two-Hand-Control Kits with STB Touch Buttons
CAUTION
!
Power Before Checkout
Before performing the initial
checkout procedure, make certain all
power is dis con nect ed from the machine
to be controlled. Temporarily dis con nect
the wires connected to the outputs of
the DUO-TOUCH SG Safety Module at
terminals 13/14 and 23/24.
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
... Disconnect

Advertisement

Table of Contents
loading

Table of Contents